Bance Manohar, Morris David P, Van Wijhe Rene
E.A.R Laboratory, Division of Otolaryngology, Department of Surgery, Dalhousie University, Halifax, Nova Scotia.
J Otolaryngol. 2007 Apr;36(2):113-9. doi: 10.2310/7070.2007.0008.
The effects of changing prosthesis mass on middle ear transmission have not been previously systematically studied. Neither has the effect of stapes tendon sectioning. These are important parameters that can be surgically varied.
Because the middle ear is compliance dominated at low frequencies, prosthesis mass will affect transmission of higher frequencies in the middle ear.
Eight fresh cadaveric temporal bones, with the incus removed, were loaded with a replacement prosthesis from the tympanic membrane to the stapes head. Laser Doppler vibrometry was used to measure stapes footplate vibrations. Vibrations were measured in response to chirps from 250 to 8 kHz at 90 dB SPL in the ear canal. The unloaded prosthesis mass was approximately 16 mg. Loadings with masses of approximately 2, 12, and 30 mg were placed on the stem. Recordings were repeated after cutting the stapes tendon.
Mass loading affected the higher frequencies only, with significant effects only above 4 kHz. There was little low-frequency effect. Stapes tendon section showed an improvement in the lower frequencies but did not reach statistical significance.
Mass of prostheses affects mainly higher frequencies. There is no drop in lower frequencies from using lower masses, so lighter-mass prostheses may be preferred. Stapes tendon section does not have a detrimental effect on middle ear transmission after ossiculoplasty.
此前尚未对改变假体质量对中耳传导的影响进行系统研究。镫骨肌腱切断术的影响也未被研究过。这些都是可以通过手术改变的重要参数。
由于中耳在低频时以顺应性为主,假体质量将影响中耳较高频率的传导。
八具新鲜尸体颞骨,去除砧骨后,从鼓膜到镫骨头植入替代假体。使用激光多普勒振动测量法测量镫骨足板振动。在耳道内以90 dB SPL的声压级测量对250至8 kHz啁啾声的振动响应。未加载的假体质量约为16 mg。在假体柄上加载质量约为2、12和30 mg的物体。切断镫骨肌腱后重复记录。
质量加载仅影响较高频率,仅在4 kHz以上有显著影响。低频影响很小。镫骨肌腱切断术在低频时有改善,但未达到统计学意义。
假体质量主要影响较高频率。使用较轻质量的假体不会导致低频下降,因此可能更倾向于使用较轻质量的假体。镫骨肌腱切断术在听骨链成形术后对中耳传导没有不利影响。