Bashashati Ali, Nouredin Borna, Ward Rabab K, Lawrence Peter, Birch Gary E
Department of Electrical and Computer Engineering, University of British Columbia, 2332 Main Mall, Vancouver, BC, Canada.
Clin Neurophysiol. 2007 Jul;118(7):1639-47. doi: 10.1016/j.clinph.2007.03.020. Epub 2007 Apr 26.
To test the performance of an EEG-based self-paced brain interface when data contaminated with eye-blink artefacts are included in the evaluation.
Two different designs of a self-paced brain interface (the low frequency-asynchronous switch design, LF-ASD) are evaluated and compared using offline data from eight subjects. The true positive rates of the two designs are compared for three cases: (a) data containing eye-blink artefacts are excluded from the input; (b) all data, including eye-blinks, are included as input but the output decisions are inactivated during eye-blink artefacts; (c) all the data, including eye-blinks, are included as input and the output decisions are reported in all times including during eye-blink artefacts.
The true positive rates of one design of the LF-ASD (LF-ASD-V5) for case (c) and of another design (LF-ASD-V4) for case (b) are 40.5% and 42.4%, respectively, for false positive rates of 1%.
The true positive rates of LF-ASD-V5 when eye-blinks are included in the analysis deteriorate slightly compared to when the output during eye-blink artefacts is inactivated in LF-ASD-V4.
LF-ASD-V5 allows the device to be functional at all times and can handle artefacts better than LF-ASD-V4. If a slight decrease in true positive rates is acceptable, no further devices are needed to record the electro-oculogram (EOG) for detecting eye-blinks.
在评估中纳入受眨眼伪迹污染的数据时,测试基于脑电图的自定节奏脑机接口的性能。
使用来自8名受试者的离线数据,对自定节奏脑机接口的两种不同设计(低频异步开关设计,LF-ASD)进行评估和比较。比较两种设计在三种情况下的真阳性率:(a)输入中排除包含眨眼伪迹的数据;(b)所有数据,包括眨眼数据,都作为输入,但在眨眼伪迹期间输出决策无效;(c)所有数据,包括眨眼数据,都作为输入,并且在所有时间报告输出决策,包括眨眼伪迹期间。
对于1%的假阳性率,LF-ASD的一种设计(LF-ASD-V5)在情况(c)下的真阳性率为40.5%,另一种设计(LF-ASD-V4)在情况(b)下的真阳性率为42.4%。
与LF-ASD-V4中眨眼伪迹期间输出无效相比,分析中包含眨眼时LF-ASD-V5的真阳性率略有下降。
LF-ASD-V5允许设备始终保持功能,并且比LF-ASD-V4能更好地处理伪迹。如果真阳性率的轻微下降是可以接受的,则无需进一步的设备来记录眼电图(EOG)以检测眨眼。