Giguère Dominic, Olivié Gilles, Vidal François, Toetsch Stéphanie, Girard Guillaume, Ozaki Tsuneyuki, Kieffer Jean-Claude, Nada Ossama, Brunette Isabelle
Institut National de la Recherche Scientifique-Energie, Matériaux et Télécommunications, Varennes, Quebec, Canada.
J Opt Soc Am A Opt Image Sci Vis. 2007 Jun;24(6):1562-8. doi: 10.1364/josaa.24.001562.
The surface ablation threshold fluence of fused silica and two porcine cornea layers, the epithelium and the stroma, is characterized as a function of the laser pulse duration in the range of 100 fs-5 ps for a wavelength of 800 nm (Ti:sapphire laser system). The plateaulike region observed between 100 fs and 1 ps for the corneal layers indicates that for use in laser surgery, laser pulse durations chosen within this range should be practically equivalent. Our model predicts that the ablation threshold will decrease rapidly for pulse durations in the low end of the femtosecond regime.