Suppr超能文献

早期加载时由不同幅度和频率组成的恒定应变率对种植体周围骨(再)重塑的影响。

Effect of constant strain rate, composed of varying amplitude and frequency, of early loading on peri-implant bone (re)modelling.

作者信息

De Smet E, Jaecques S V N, Jansen J J, Walboomers F, Vander Sloten J, Naert I E

机构信息

Department of Prosthetic Dentistry/BIOMAT Research Group, School of Dentistry, Oral Pathology and Maxillofacial Surgery, K U Leuven, Kapucijnenvoer, Leuven, Belgium.

出版信息

J Clin Periodontol. 2007 Jul;34(7):618-24. doi: 10.1111/j.1600-051X.2007.01082.x.

Abstract

AIM

Examine the effect of varying components of strain rate -- amplitude versus frequency -- while maintaining a constant strain rate of early controlled mechanical loading on implant stability, peri-implant bone mass and bone-to-implant contact.

MATERIAL AND METHODS

Three groups of guinea-pigs received TiO2 -blasted implants in both tibiae. One week after installation test implants were loaded 5 days/week during 4 weeks. The contra-lateral implants were the unloaded controls. Strain rate was kept constant (1600 micro epsilon/s), while amplitude and frequency were varied per group. Implant stability was followed by resonance frequency analysis. Animals were sacrificed, and ground sections were prepared to rate bone-to-implant contact and bone mass.

RESULTS

All implants (n=78) integrated uneventfully. A significant positive effect (p=0.03) of early loading on bone mass was observed in the distal medullar cavity. A significant difference in bone mass between test and control implants was evidenced between the groups (p=0.03 and 0.04). A significant increase in implant stability and bone-to-implant contact could not be shown.

CONCLUSIONS

Early controlled stimulation of peri-implant bone is related to amplitude/frequency and not to strain rate as such, considering a constant stimulation time. An increase of bone mass around early-loaded implants was shown. This cortical bone model is most sensitive to low-frequency/high-amplitude stimulation.

摘要

目的

在保持早期可控机械加载的应变速率恒定的同时,研究应变速率的不同组成部分——幅度与频率——对种植体稳定性、种植体周围骨量和骨与种植体接触的影响。

材料与方法

三组豚鼠双侧胫骨均植入经二氧化钛喷砂处理的种植体。植入测试种植体一周后,在4周内每周加载5天。对侧种植体作为未加载的对照。应变速率保持恒定(1600微应变/秒),而每组的幅度和频率有所不同。通过共振频率分析跟踪种植体稳定性。处死动物,制备磨片以评估骨与种植体接触及骨量。

结果

所有种植体(n = 78)均顺利整合。在远侧髓腔内观察到早期加载对骨量有显著的积极影响(p = 0.03)。各实验组与对照组种植体之间的骨量存在显著差异(p = 0.03和0.04)。未显示种植体稳定性和骨与种植体接触有显著增加。

结论

考虑到刺激时间恒定,早期对种植体周围骨的可控刺激与幅度/频率有关,而非应变速率本身。结果显示早期加载种植体周围的骨量增加。这种皮质骨模型对低频/高幅度刺激最为敏感。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验