Porta Alberto, Gnecchi-Ruscone Tomaso, Tobaldini Eleonora, Guzzetti Stefano, Furlan Raffaello, Montano Nicola
Universita' degli Studi di Milano, Dipartimento di Tecnologie per la Salute, Istituto Ortopedico Galeazzi, Laboratorio di Modellistica di Sistemi Complessi, Via R. Galeazzi 4, 20161 Milan, Italy.
J Appl Physiol (1985). 2007 Oct;103(4):1143-9. doi: 10.1152/japplphysiol.00293.2007. Epub 2007 Jun 14.
Complexity (or its opposite, regularity) of heart period variability has been related to age and disease but never linked to a progressive shift of the sympathovagal balance. We compare several well established estimates of complexity of heart period variability based on entropy rates [i.e., approximate entropy (ApEn), sample entropy (SampEn), and correct conditional entropy (CCE)] during an experimental protocol known to produce a gradual shift of the sympathovagal balance toward sympathetic activation and vagal withdrawal (i.e., the graded head-up tilt test). Complexity analysis was carried out in 17 healthy subjects over short heart period variability series ( approximately 250 cardiac beats) derived from ECG recordings during head-up tilt with table inclination randomly chosen inside the set {0, 15, 30, 45, 60, 75, 90}. We found that 1) ApEn does not change significantly during the protocol; 2) all indices measuring complexity based on entropy rates, including ad hoc corrections of the bias arising from their evaluation over short data sequences (i.e., corrected ApEn, SampEn, CCE), evidence a progressive decrease of complexity as a function of the tilt table inclination, thus indicating that complexity is under control of the autonomic nervous system; 3) corrected ApEn, SampEn, and CCE provide global indices that can be helpful to monitor sympathovagal balance.
心率变异性的复杂性(或其相反的规律性)已与年龄和疾病相关,但从未与交感迷走神经平衡的渐进性变化联系起来。我们在一个已知会使交感迷走神经平衡逐渐向交感神经激活和迷走神经退缩转变的实验方案(即分级头高位倾斜试验)中,比较了几种基于熵率的成熟的心率变异性复杂性估计方法[即近似熵(ApEn)、样本熵(SampEn)和正确条件熵(CCE)]。对17名健康受试者在头高位倾斜过程中从心电图记录中获取的短心率变异性序列(约250次心跳)进行复杂性分析,倾斜台角度在集合{0, 15, 30, 45, 60, 75, 90}中随机选择。我们发现:1)在该方案中ApEn没有显著变化;2)所有基于熵率测量复杂性的指标,包括对在短数据序列上评估产生的偏差进行的特殊校正(即校正后的ApEn、SampEn、CCE),都表明复杂性随着倾斜台角度的增加而逐渐降低,这表明复杂性受自主神经系统控制;3)校正后的ApEn、SampEn和CCE提供了可有助于监测交感迷走神经平衡的全局指标。