在医用加速器领域中,含有硼作为中子探测器的电离室。

Ionisation chamber containing boron as a neutron detector in medical accelerator fields.

作者信息

Zielczynski M, Gryzinski M A, Golnik N, Tulik P

机构信息

Institute of Atomic Energy, 05-400 Otwock-Swierk, Poland.

出版信息

Radiat Prot Dosimetry. 2007;126(1-4):274-7. doi: 10.1093/rpd/ncm057. Epub 2007 Jun 16.

Abstract

A combination of the recombination principle of H(10) measurements with the use of the ionisation chambers containing boron has been presented, in order to increase the relative sensitivity of the chamber to neutrons by a factor close to the radiation quality factor of photoneutrons. Three types of the chambers were investigated. Two of them were filled with BF(3) and the third one contained electrodes covered with B(4)C. All the chambers were placed in paraffin moderators. The response of the chambers was investigated, depending on gas pressure and polarising voltage. The results showed that it was possible to obtain nearly the same response of the chamber to H(10) for photons and neutrons in a restricted energy range; however, further investigations are needed to make an optimum design.

摘要

提出了一种将H(10)测量的复合原理与使用含硼电离室相结合的方法,以使电离室对中子的相对灵敏度提高到接近光中子辐射品质因数的倍数。研究了三种类型的电离室。其中两种填充有BF(3),第三种含有覆盖有B(4)C的电极。所有电离室都放置在石蜡慢化剂中。研究了电离室的响应与气压和极化电压的关系。结果表明,在一个受限的能量范围内,电离室对光子和中子的H(10)响应几乎可以相同;然而,还需要进一步研究以进行优化设计。