两种带角度种植体印模技术的准确性。
Accuracy of two impression techniques with angulated implants.
作者信息
Conrad Heather J, Pesun Igor J, DeLong Ralph, Hodges James S
机构信息
Division of Prosthodontics, Department of Restorative Sciences, School of Dentistry, University of Minnesota, Minneapolis, Minn. 55455, USA.
出版信息
J Prosthet Dent. 2007 Jun;97(6):349-56. doi: 10.1016/S0022-3913(07)60023-7.
STATEMENT OF PROBLEM
Accurate recording of implant locations is required so that definitive restorations are properly supported and do not place additional stress on the implants. Angulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast.
PURPOSE
The purpose of this study was to determine the effect the combined interaction of impression technique, implant angulation, and implant number has on the accuracy of implant definitive casts.
MATERIAL AND METHODS
One definitive stone cast was fabricated for each of 6 experimental groups and 1 control group. All 7 definitive casts had 3 implants arranged in a triangular pattern creating a plane. In the 6 experimental groups, the center implant was perpendicular to the plane of the cast while the outer implants had 5, 10, or 15 degrees convergence towards or divergence away from the center implant. The control definitive cast had all 3 implants parallel to each another and perpendicular to the plane of the cast. Five open tray and 5 closed tray addition silicone impressions were made of each definitive cast. Impressions were poured with type IV dental stone, and a fine tip measuring stylus was used to record multiple axis (X-Y-Z) coordinates on the top surface of the implant hex and on the cast base. Computer software was used to align the data sets and vector calculations determined the difference in degrees between the implant angles in the definitive cast and the duplicate casts. Statistical analysis used repeated-measures ANOVA (alpha=.05) with post-hoc tests of significant interactions.
RESULTS
The angle errors for the closed and open tray impression techniques did not differ significantly (P=.22). Implant angulations and implant numbers differed in average angle errors but not in any easily interpreted pattern (P<.001). The combined interaction of impression technique, implant angulation, and implant number had no effect on the accuracy of the duplicate casts compared to the definitive casts (P=.19).
CONCLUSIONS
The average angle errors for the closed and open tray impression techniques did not differ significantly. There was no interpretable pattern of average angle errors in terms of implant angulation and implant number. The magnitude of distortion was similar for all combinations of impression technique, implant angulation, and implant number.
问题陈述
需要准确记录种植体位置,以便最终修复体得到适当支撑,且不会给种植体施加额外压力。成角种植体可能导致印模不准确,并且印模技术可能会影响最终模型的准确性。
目的
本研究的目的是确定印模技术、种植体角度和成种植体数量的联合相互作用对种植体最终模型准确性的影响。
材料与方法
为6个实验组和1个对照组分别制作一个最终石膏模型。所有7个最终模型均有3个种植体呈三角形排列形成一个平面。在6个实验组中,中间种植体垂直于模型平面,而外侧种植体向中间种植体汇聚或背离中间种植体呈5度、10度或15度。对照最终模型的所有3个种植体相互平行且垂直于模型平面。对每个最终模型制作5个开放托盘和5个封闭托盘加成型硅橡胶印模。印模用IV型牙科石膏灌注,并用细尖测量探针在种植体六角形顶面和模型底座上记录多轴(X - Y - Z)坐标。使用计算机软件对齐数据集,向量计算确定最终模型和复制模型中种植体角度之间的度数差异。统计分析采用重复测量方差分析(α = 0.05)以及显著相互作用的事后检验。
结果
封闭托盘和开放托盘印模技术的角度误差无显著差异(P = 0.22)。种植体角度和种植体数量的平均角度误差不同,但无任何易于解释的模式(P < 0.001)。与最终模型相比,印模技术、种植体角度和种植体数量的联合相互作用对复制模型的准确性没有影响(P = 0.19)。
结论
封闭托盘和开放托盘印模技术的平均角度误差无显著差异。在种植体角度和种植体数量方面,平均角度误差没有可解释的模式。印模技术、种植体角度和种植体数量的所有组合的变形程度相似。