氡校准室组件、探测器精度及相关运行结果。

Radon calibration chamber assembly, detector accuracy, and pertinent operational findings.

作者信息

Distenfeld C H

机构信息

TCS Industries, Inc., 4326 Crestview Road, Harrisburg, PA 17112, USA.

出版信息

Health Phys. 2007 Aug;93(2 Suppl):S144-50. doi: 10.1097/01.HP.0000267006.55621.2f.

Abstract

Reliable radon laboratory operations motivated the construction of three radon gas calibration chambers. One chamber is used for background calibrations while the other two cover a radon gas concentration range of 110 to >5,550 Bq m(-3) (3-150 pCi L(-1)). The chambers entered commercial service, for tertiary radon calibration chambers, after review and listing by the National Radon Safety Board. The chambers were used since 2003 to calibrate over 500 activated charcoal (AC) detectors, half open face, and the remainder a diffusion barrier type, and >150 continuous radon (CR) monitors. Nearly all the CR devices were Sun Nuclear model 1027. Analysis of the calibration results show the overall AC measurement uncertainties, expressed as standard deviations of the relative percent differences, R%D, were <10% and were about the same as the Sun Nuclear CR devices. The diffusion barrier AC detectors displayed a smaller uncertainty than the CR monitor group. All but one CR monitor satisfied the U.S. EPA Radon Proficiency Program requirement of +/-25%. In view of the similar R%D between CR and AC detectors, good agreement was found for all simultaneous field radon measurements with CR and single AC devices. The U.S. EPA appears to have adopted a position that CR devices are superior to AC detectors. Neither the present results nor U.S. EPA's published detector uncertainties support this presumed position.

摘要

可靠的氡实验室操作促使建造了三个氡气校准室。一个校准室用于本底校准,另外两个校准室的氡气浓度范围为110至>5550 Bq m(-3)(3 - 150 pCi L(-1))。这些校准室经国家氡安全委员会审查并列入名录后,作为三级氡校准室投入商业服务。自2003年以来,这些校准室用于校准500多个活性炭(AC)探测器,其中一半为半开放式,其余为扩散阻挡型,以及>150台连续氡(CR)监测仪。几乎所有的CR设备都是太阳核公司的1027型。校准结果分析表明,以相对百分比差异的标准偏差表示的AC测量总体不确定度<10%,与太阳核CR设备的不确定度大致相同。扩散阻挡型AC探测器的不确定度比CR监测仪组小。除一台CR监测仪外,所有CR监测仪均满足美国环保署氡熟练度计划±25%的要求。鉴于CR探测器和AC探测器之间的相对百分比差异相似,在所有CR设备与单个AC设备同时进行的现场氡测量中都发现了良好的一致性。美国环保署似乎采取了一种立场,即CR设备优于AC探测器。目前的结果和美国环保署公布的探测器不确定度均不支持这一假定立场。

相似文献

1
Radon calibration chamber assembly, detector accuracy, and pertinent operational findings.
Health Phys. 2007 Aug;93(2 Suppl):S144-50. doi: 10.1097/01.HP.0000267006.55621.2f.
2
Blind testing of commercially available short-term radon detectors.
Health Phys. 2008 Jun;94(6):548-57. doi: 10.1097/01.HP.0000309764.46086.23.
3
Radon measurement quality, how accurate is reasonable?
Health Phys. 2011 Nov;101 Suppl 3:S148-53. doi: 10.1097/HP.0b013e31821f1276.
4
Field comparison of commercially available short-term radon detectors.
Health Phys. 2006 Sep;91(3):221-6. doi: 10.1097/01.HP.0000206040.55298.ce.
5
Uncertainties evaluation for electrets based devices used in radon detection.
Radiat Prot Dosimetry. 2005;113(1):64-9. doi: 10.1093/rpd/nch420. Epub 2004 Nov 30.
7
Radon monitor calibration using NIST radon emanation standards: steady flow method.
Radiat Prot Dosimetry. 2005;113(1):70-4. doi: 10.1093/rpd/nch421. Epub 2004 Nov 23.
8
One cubic metre NIST traceable radon test chamber.
Radiat Prot Dosimetry. 2008;128(4):500-2. doi: 10.1093/rpd/ncm430. Epub 2007 Sep 29.
9
Evaluation of efficiency calibration parameters of the LR-115 radon detector.
Health Phys. 2010 May;98 Suppl 2:S63-8. doi: 10.1097/HP.0b013e3181d27376.
10
Field comparison of two different passive radon detectors.
Radiat Prot Dosimetry. 2005;113(4):438-41. doi: 10.1093/rpd/nch475. Epub 2005 Mar 23.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验