Suppr超能文献

用于检测PAG的五种放射免疫分析系统的比较:奶牛早期妊娠检测能力

Comparison of five radioimmunoassay systems for PAG measurement: ability to detect early pregnancy in cows.

作者信息

Ayad A, Sousa N M, Sulon J, Iguer-Ouada M, Beckers J F

机构信息

Laboratory of Physiology of Animal Reproduction, Faculty of Veterinary Medicine, University of Liege, Liege, Belgium.

出版信息

Reprod Domest Anim. 2007 Aug;42(4):433-40. doi: 10.1111/j.1439-0531.2006.00804.x.

Abstract

This study was conducted to describe the minimum detection limit, reproducibility, accuracy, specificity and parallelism of different pregnancy-associated glycoprotein radioimmunoassay (PAG-RIA) systems: RIA-497, RIA-706, RIA-780, RIA-809 and RIA-Pool. Their ability to distinguish between non-pregnant and pregnant females at day 30 after artificial insemination (AI) was investigated. The antisera were raised in rabbits against different PAG preparations. All RIA systems proved to be sensitive, repeatable and accurate for measuring PAG concentrations. The dilutions of plasma samples taken at an early stage of pregnancy were found to be parallel to the standard curves. No cross-reaction was observed with different carbohydrates, either with Pregnant Mare Serum Gonadotropin (PMSG) or human Chorionic Gonadotropin (hCG). The concentrations of PAG in pregnant females at day 30 after AI were shown to be higher with the use of antisera R#706, R#780, R#809 and Pool when compared with antiserum R#497. All the RIA systems gave 100% sensitivity and negative predictive values. On the other hand, the use of antisera R#780 and R#809 resulted in lower specificity and positive predictive values. The present study clearly shows that the ability of PAG-RIA systems to diagnose pregnancy specifically at day 30 after AI can be improved by using a combination of antisera raised against different forms of PAG.

摘要

本研究旨在描述不同妊娠相关糖蛋白放射免疫分析(PAG - RIA)系统:RIA - 497、RIA - 706、RIA - 780、RIA - 809和RIA - Pool的最低检测限、重复性、准确性、特异性和平行性。研究了它们在人工授精(AI)后第30天区分未怀孕和怀孕雌性动物的能力。抗血清是用兔针对不同的PAG制剂制备的。所有RIA系统在测量PAG浓度方面均被证明是灵敏、可重复且准确的。发现在妊娠早期采集的血浆样本稀释液与标准曲线平行。未观察到与不同碳水化合物、孕马血清促性腺激素(PMSG)或人绒毛膜促性腺激素(hCG)有交叉反应。与抗血清R#497相比,使用抗血清R#706、R#780、R#809和Pool时,AI后第30天怀孕雌性动物体内的PAG浓度更高。所有RIA系统的灵敏度和阴性预测值均为100%。另一方面,使用抗血清R#780和R#809导致特异性和阳性预测值较低。本研究清楚地表明,通过使用针对不同形式PAG制备的抗血清组合,可以提高PAG - RIA系统在AI后第30天特异性诊断妊娠的能力。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验