Abstract

PURPOSE

To illustrate the successful management of an occult intraocular foreign body (IOFB) lodged posterior to the iris causing persistent endophthalmitis.

METHODS

Two young male patients presented with corneal laceration, endophthalmitis and foreign body on X-ray but not localized by B-scan ultrasonography or gonioscopy.

RESULTS

Ultrasound Biomicroscopy (UBM) localized the foreign body lodged between the posterior iris and anterior lens surface accurately, which was successfully removed through the limbus using an external magnet.

CONCLUSIONS

UBM is invaluable to accurately localize occult IOFBs lodged in the posterior iris or ciliary body region, which ensures good visual rehabilitation of these hitherto considered difficult cases.

摘要

目的

阐述对隐匿性眼内异物(IOFB)成功的处理,该异物嵌顿于虹膜后方并导致持续性眼内炎。

方法

两名年轻男性患者出现角膜裂伤、眼内炎,X线检查发现有异物,但B超超声检查或前房角镜检查未定位到异物。

结果

超声生物显微镜(UBM)准确地将异物定位在虹膜后和晶状体前表面之间,通过角膜缘使用外部磁铁成功取出异物。

结论

UBM对于准确定位隐匿于虹膜后或睫状体区域的IOFB非常重要,这确保了这些以往被认为棘手的病例能获得良好的视力恢复。