Suppr超能文献

准分子原位角膜磨镶术后角膜后表面的长期稳定性。

Long-term stability of the posterior cornea after laser in situ keratomileusis.

作者信息

Ciolino Joseph B, Khachikian Stephen S, Cortese Michael J, Belin Michael W

机构信息

Albany Medical College, Albany, New York, USA.

出版信息

J Cataract Refract Surg. 2007 Aug;33(8):1366-70. doi: 10.1016/j.jcrs.2007.04.016.

Abstract

PURPOSE

To study long-term changes in posterior corneal elevation after laser in situ keratomileusis (LASIK) using Scheimpflug topography (Pentacam, Oculus, Inc.) in eyes 1 year after LASIK.

SETTING

Department of Ophthalmology, Albany Medical Center, and a private practice, Albany, New York, USA.

METHODS

One hundred two myopic eyes of 52 consecutive patients presenting for their 1-year follow-up were prospectively evaluated using the Pentacam to determine elevation changes to the posterior corneal surface between preoperative and 1-year postoperative measurements. Changes in posterior elevation were performed by comparing the best-fit sphere preoperatively and postoperatively with a fixed reference sphere determined by the central 9.0 mm preoperative cornea. Statistical and graphical analyses were performed.

RESULTS

One hundred two post-LASIK eyes (mean correction -4.33 diopters; mean ablation depth 68.70 microm; mean estimated residual bed thickness 327 microm) had a mean posterior displacement of -0.47 microm +/- 3.48 (SD) (range -10.0 to +7 microm). The mean follow-up period was 13.6 months (range 8.8 to 19.3 months).

CONCLUSIONS

In this population, no patient had significant forward protrusion of the posterior corneal surface a mean of 14 months after LASIK. The posterior cornea in post-LASIK myopic eyes was very stable. Contrary to results in previous studies, progressive changes to the posterior corneal surface did not routinely occur after LASIK performed within established parameters.

摘要

目的

使用眼前节分析系统(Pentacam,Oculus公司)研究准分子原位角膜磨镶术(LASIK)术后1年角膜后表面高度的长期变化。

设置

美国纽约奥尔巴尼医学中心眼科及一家私人诊所。

方法

对连续52例患者的102只近视眼睛进行1年随访,前瞻性地使用Pentacam评估术前和术后1年角膜后表面高度的变化。通过比较术前和术后的最佳拟合球镜与由术前中央9.0mm角膜确定的固定参考球镜来进行后表面高度变化分析。进行了统计和图形分析。

结果

102只LASIK术后眼睛(平均矫正度数-4.33屈光度;平均切削深度68.70微米;平均估计剩余角膜床厚度327微米)后表面平均位移为-0.47微米±3.48(标准差)(范围-10.0至+7微米)。平均随访期为13.6个月(范围8.8至19.3个月)。

结论

在该人群中,LASIK术后平均14个月没有患者出现角膜后表面明显向前突出。LASIK术后近视眼中的角膜后表面非常稳定。与先前研究结果相反,在既定参数范围内进行LASIK术后,角膜后表面通常不会出现渐进性变化。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验