Suppr超能文献

对暴露于泰瑟枪的人体受试者进行心脏监测。

Cardiac monitoring of human subjects exposed to the taser.

作者信息

Levine Saul D, Sloane Christian M, Chan Theodore C, Dunford James V, Vilke Gary M

机构信息

Department of Emergency Medicine, University of California, San Diego (UCSD) Medical Center, San Diego, California, USA.

出版信息

J Emerg Med. 2007 Aug;33(2):113-7. doi: 10.1016/j.jemermed.2007.02.018. Epub 2007 Jun 13.

Abstract

The Taser (TASER International, Scottsdale, AZ) is a high-voltage, low-amperage device used by many law enforcement agencies. Our objective in this study was to evaluate for rhythm changes utilizing cardiac monitoring during deployment of the Taser on volunteers. A prospective, observational study evaluated law enforcement personnel who had continuous electrocardiographic monitoring immediately before, during, and after having a voluntary exposure to the Taser X-26. Changes in cardiac rate, rhythm, ectopy, morphology, and conduction intervals were measured. A total of 105 subjects were evaluated. The mean shock duration was 3.0 s (range 0.9-5 s). Mean heart rate increased 15 beats/min (95% CI 12.6-18.3), from 122 beats/min before shock to 137 beats/min immediately after shock. One subject had a single premature ventricular contraction both before and after the shock, but no other subject developed ectopy or dysrhythmia. Poor inter-rater agreement prevented determination of the overall effect of shock on conduction intervals. However, several interpretable tracings demonstrated change in QT duration-either shortening or prolongation after shock. Human subjects exposed to a brief shock from the Taser developed significant increases in heart rate, but there were no cardiac dysrhythmias or morphologic changes. Alterations in the QT interval were observed in some subjects but their true incidence and clinical significance are unknown.

摘要

泰瑟枪(泰瑟国际公司,亚利桑那州斯科茨代尔)是一种许多执法机构都在使用的高电压、低电流装置。我们开展这项研究的目的是,在志愿者使用泰瑟枪期间利用心脏监测来评估心律变化。一项前瞻性观察性研究对在自愿接触泰瑟X-26之前、期间和之后接受连续心电图监测的执法人员进行了评估。测量了心率、心律、异位心律、形态和传导间期的变化。总共评估了105名受试者。平均电击持续时间为3.0秒(范围0.9 - 5秒)。平均心率增加了15次/分钟(95%可信区间12.6 - 18.3),从电击前的122次/分钟增加到电击后的即刻137次/分钟。一名受试者在电击前后均出现一次室性早搏,但没有其他受试者出现异位心律或心律失常。评分者间一致性较差,无法确定电击对传导间期的总体影响。然而,几份可解读的心电图显示QT间期有变化——电击后要么缩短要么延长。接触泰瑟枪短暂电击的人体受试者心率显著增加,但未出现心脏心律失常或形态学改变。在一些受试者中观察到QT间期有改变,但其真实发生率和临床意义尚不清楚。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验