The objective of this study was to determine the reliability of repeated plantar pressure distribution measurements during normal gait across multiple testing sessions. Testing sessions were conducted on 5 separate days at approximately the same time of day. Nine subjects (five males, four females, age 26+/-8.4 years) who were free of any musculoskeletal injury were recruited. A capacitive pressure distribution platform (EMED AT, Novel GmbH, Munich, Germany), sampling at 50Hz was used to collect plantar pressure patterns during barefoot walking at a self-selected speed. Four parameters were investigated: peak pressure, maximum force, impulse, and contact time, and these were investigated in 10 areas of the foot after using the PRC mask method of subdividing the foot into ten anatomical areas of interest. Individual means of all the five repeated trials for each foot were calculated, and these values were used to calculate intraclass correlation coefficients (ICC) and coefficients of variation (CoV) for all parameters. The results of this investigation show a generally good level of reliability, the quality of which is dependent on the region of the foot and the parameter investigated. Areas with typically high loading characteristics, such as the central forefoot showed a higher level of reliability in the ICC's (>0.9) than less loaded areas such as the medial midfoot (<0.8). The conclusion of this study is that plantar pressure distribution measurements can be used in comparative evaluations since the measures of repeatability are satisfactory for the parameters and foot regions usually used in the investigation of clinical populations such as neuropathic diabetics.

摘要

本研究的目的是确定在多个测试环节中,正常步态期间重复进行足底压力分布测量的可靠性。测试环节在大约相同的每日时间于5个不同日期进行。招募了9名无任何肌肉骨骼损伤的受试者(5名男性,4名女性,年龄26±8.4岁)。使用一个以50Hz采样的电容式压力分布平台(EMED AT,德国慕尼黑Novel GmbH公司),在赤足以自选速度行走期间收集足底压力模式。研究了四个参数:峰值压力、最大力、冲量和接触时间,并且在使用将足部细分为十个感兴趣解剖区域的PRC掩码方法后,在足部的10个区域对这些参数进行了研究。计算了每只脚所有五次重复试验的个体均值,并且使用这些值计算所有参数的组内相关系数(ICC)和变异系数(CoV)。本研究结果显示出总体良好的可靠性水平,其质量取决于足部区域和所研究的参数。具有典型高负荷特征的区域,如前脚掌中部,在ICC方面显示出比负荷较小的区域(如足内侧中部,<0.8)更高的可靠性水平(>0.9)。本研究的结论是,足底压力分布测量可用于比较评估,因为对于诸如神经性糖尿病患者等临床人群调查中通常使用的参数和足部区域,重复性测量结果令人满意。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验