Melucci Dora, Locatelli Clinio
Department of Chemistry "G. Ciamician", University of Bologna, Via F. Selmi 2, I-40126 Bologna, Italy.
Ann Chim. 2007 May-Jun;97(5-6):373-84. doi: 10.1002/adic.200790022.
The present work reports analytical results relevant to voltammetric determination of Pt(II), Pd(II), Rh(III) [Platinum Group Metals (PGMs)] and Pb(II) in superficial water sampled in sites differently influenced by vehicle traffic, especially considering their temporal behaviour. For all the elements, in addition to detection limits, precision, expressed as relative standard deviation (s(r) %) and accuracy, expressed as percentage recovery (R %) are also reported. In all cases they show to be good, being the former lower than 6% and the latter in the range 94-105%. A critical comparison with spectroscopic measurements is also discussed.
本研究报告了与伏安法测定受车辆交通影响程度不同的地点采集的地表水中的Pt(II)、Pd(II)、Rh(III) [铂族金属(PGMs)]和Pb(II)相关的分析结果,尤其考虑了它们的时间行为。对于所有元素,除了检测限外,还报告了以相对标准偏差(s(r) %)表示的精密度和以回收率(R %)表示的准确度。在所有情况下,它们都表现良好,前者低于6%,后者在94 - 105%范围内。还讨论了与光谱测量的关键比较。