[血液中离子钙部分:对不同方法学因素的依赖性]

[The ionized calcium fraction of the blood: dependence on different methodical factors].

作者信息

Kölling K

机构信息

Physiologischen Instituten, Ludwig-Maximilians-Universität München.

出版信息

Zentralbl Veterinarmed A. 1991 Oct;38(8):629-38.

PMID:1771985
Abstract

In the present study the influence of different methodical factors (analyzer with ion-selective electrodes used, anticoagulation of blood samples with heparin, storing of samples at different temperatures) on the concentration of ionized calcium in blood was investigated. It could be shown that nowadays' systems for analysis of ionized calcium (ORION SS-20, AVL 980, NOVA 2 and 8, ICA 1) yield reproducible values for human as well as canine blood. System-related differences point to a varying degree of interferences on the ion-selective electrodes used. The concentration of ionized calcium is strongly dependent on different preanalytic factors. Heparin leads to a concentration-related reduction of calcium ions in blood. This negative impact of heparin can be overcome by substitution of the solvent for CaCl2 (2.5 mmol.l-1) without meaningful falsification of the measured values. At 4 degrees C blood samples can be stored without detectable changes in Ca++ concentration for 8 hours.

摘要

在本研究中,调查了不同方法学因素(使用离子选择性电极分析仪、用肝素对血样进行抗凝、在不同温度下储存样品)对血液中离子钙浓度的影响。结果表明,如今用于分析离子钙的系统(ORION SS - 20、AVL 980、NOVA 2和8、ICA 1)对人血和犬血均可产生可重复的值。系统相关差异表明所用离子选择性电极受到不同程度的干扰。离子钙浓度强烈依赖于不同的分析前因素。肝素会导致血液中钙离子浓度呈相关性降低。通过用CaCl2(2.5 mmol·l-1)替代溶剂可以克服肝素的这种负面影响,且不会对测量值造成有意义的伪造。在4℃下,血样可以储存8小时而Ca++浓度无明显变化。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验