Abstract

In the present study the influence of different methodical factors (analyzer with ion-selective electrodes used, anticoagulation of blood samples with heparin, storing of samples at different temperatures) on the concentration of ionized calcium in blood was investigated. It could be shown that nowadays' systems for analysis of ionized calcium (ORION SS-20, AVL 980, NOVA 2 and 8, ICA 1) yield reproducible values for human as well as canine blood. System-related differences point to a varying degree of interferences on the ion-selective electrodes used. The concentration of ionized calcium is strongly dependent on different preanalytic factors. Heparin leads to a concentration-related reduction of calcium ions in blood. This negative impact of heparin can be overcome by substitution of the solvent for CaCl2 (2.5 mmol.l-1) without meaningful falsification of the measured values. At 4 degrees C blood samples can be stored without detectable changes in Ca++ concentration for 8 hours.

摘要

在本研究中,调查了不同方法学因素(使用离子选择性电极分析仪、用肝素对血样进行抗凝、在不同温度下储存样品)对血液中离子钙浓度的影响。结果表明,如今用于分析离子钙的系统(ORION SS - 20、AVL 980、NOVA 2和8、ICA 1)对人血和犬血均可产生可重复的值。系统相关差异表明所用离子选择性电极受到不同程度的干扰。离子钙浓度强烈依赖于不同的分析前因素。肝素会导致血液中钙离子浓度呈相关性降低。通过用CaCl2(2.5 mmol·l-1)替代溶剂可以克服肝素的这种负面影响,且不会对测量值造成有意义的伪造。在4℃下,血样可以储存8小时而Ca++浓度无明显变化。