Suppr超能文献

世界贸易中心灰尘暴露后肺活量测定正常的有症状受试者的远端气道功能。

Distal airway function in symptomatic subjects with normal spirometry following World Trade Center dust exposure.

作者信息

Oppenheimer Beno W, Goldring Roberta M, Herberg Matthew E, Hofer Ira S, Reyfman Paul A, Liautaud Sybille, Rom William N, Reibman Joan, Berger Kenneth I

机构信息

Division of Pulmonary and Critical Care Medicine, Department of Medicine, New York University School of Medicine, New York, NY 10016, USA.

出版信息

Chest. 2007 Oct;132(4):1275-82. doi: 10.1378/chest.07-0913. Epub 2007 Sep 21.

Abstract

RATIONALE

Following collapse of the World Trade Center (WTC), individuals reported new-onset respiratory symptoms. Despite symptoms, spirometry often revealed normal airway function. However, bronchial wall thickening and air trapping were seen radiographically in some subjects. We hypothesized that symptomatic individuals following exposure to WTC dust may have functional abnormalities in distal airways not detectable with routine spirometry.

METHODS

One hundred seventy-four subjects with respiratory symptoms and normal spirometry results were evaluated. Impedance oscillometry (IOS) was performed to determine resistance at 5 Hz, 5 to 20 Hz, and reactance area. Forty-three subjects were also tested for frequency dependence of compliance (FDC). Testing was repeated after bronchodilation.

RESULTS

Predominant symptoms included cough (67%) and dyspnea (65%). Despite normal spirometry results, mean resistance at 5 Hz, 5 to 20 Hz, and reactance area were elevated (4.36 +/- 0.12 cm H(2)O/L/s, 0.86 +/- 0.05 cm H(2)O/L/s, and 6.12 +/- 0.50 cm H(2)O/L, respectively) [mean +/- SE]. Resistance and reactance normalized after bronchodilation. FDC was present in 37 of 43 individuals with improvement after bronchodilation.

CONCLUSIONS

Symptomatic individuals with presumed WTC dust/fume exposure and normal spirometry results displayed airway dysfunction based on the following: (1) elevated airway resistance and frequency dependence of resistance determined by IOS; (2) heterogeneity of distal airway function demonstrated by elevated reactance area on oscillometry and FDC; and (3) reversibility of these functional abnormalities to or toward normal following administration of a bronchodilator. Since spirometry results were normal in all subjects, these abnormalities likely reflect dysfunction in airways more distal to those evaluated by spirometry. Examination of distal airway function when spirometry results are normal may be important in the evaluation of subjects exposed to occupational and environmental hazards.

摘要

原理

世界贸易中心(WTC)倒塌后,一些人报告出现了新发的呼吸道症状。尽管有症状,但肺功能测定通常显示气道功能正常。然而,在一些受试者的影像学检查中发现了支气管壁增厚和气体潴留。我们推测,接触世贸中心灰尘后出现症状的个体,其远端气道可能存在常规肺功能测定无法检测到的功能异常。

方法

对174名有呼吸道症状且肺功能测定结果正常的受试者进行了评估。采用阻抗振荡法(IOS)测定5Hz、5至20Hz时的阻力以及电抗面积。43名受试者还进行了顺应性频率依赖性(FDC)测试。支气管扩张后重复测试。

结果

主要症状包括咳嗽(67%)和呼吸困难(65%)。尽管肺功能测定结果正常,但5Hz、5至20Hz时的平均阻力及电抗面积均升高(分别为4.36±0.12cmH₂O/L/s、0.86±0.05cmH₂O/L/s和6.12±0.50cmH₂O/L)[平均值±标准误]。支气管扩张后阻力和电抗恢复正常。43名受试者中有37名存在FDC,支气管扩张后有所改善。

结论

有症状且推测接触过世贸中心灰尘/烟雾但肺功能测定结果正常的个体,基于以下情况显示出气道功能障碍:(1)IOS测定的气道阻力升高及阻力频率依赖性;(2)振荡法测定的电抗面积升高及FDC显示的远端气道功能异质性;(3)使用支气管扩张剂后这些功能异常可恢复或趋于正常。由于所有受试者的肺功能测定结果均正常,这些异常可能反映了比肺功能测定所评估的气道更远端的气道功能障碍。在评估接触职业和环境危害的受试者时,当肺功能测定结果正常时检查远端气道功能可能很重要。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验