Wester Sara T, Rizzo Joseph F, Balkwill M David, Wall Conrad
Bascom Palmer Eye Institute, Miami, Florida 33136, USA.
Invest Ophthalmol Vis Sci. 2007 Oct;48(10):4542-8. doi: 10.1167/iovs.06-1206.
To evaluate the efficacy of using optokinetic nystagmus (OKN) as an objective measurement of vision in severely visually impaired patients, in whom it is difficult to measure visual function reliably. Objective visual acuity (VA) measurements would be useful in the pre-and postoperative assessment of severely visually impaired patients who are potential candidates for visual rehabilitation strategies, such as retinal prostheses, neural and stem cell transplantation, and molecular approaches.
Full-field visual stimuli were used to evoke horizontal OKN responses in 17 subjects. Eye movements were recorded and analyzed to determine the maximum stimulus velocity (V(max)) at which subjects could maintain an OKN response. This endpoint was compared to logMAR VA and Goldmann visual field (VF) test
results. V(max) was dependent on VA, VF, and the spatial frequency (SF) of the stimulus, yielding the equation V(max) = 14.2 . log(VA) - 6.20 . log(SF) + 0.22 . VF + 25.0. The findings suggest that V(max) in the presence of full-field OKN stimuli may provide an objective measure of VA and peripheral vision.
OKN testing may be useful as an additional, more objective means of assessing visual function in a select group of severely visually impaired patients who are being considered as candidates for new visual rehabilitative strategies.
评估使用视动性眼震(OKN)作为严重视力受损患者视力客观测量方法的有效性,这类患者难以可靠地测量视觉功能。客观视力(VA)测量对于严重视力受损患者的术前和术后评估很有用,这些患者是视觉康复策略(如视网膜假体、神经和干细胞移植以及分子方法)的潜在候选者。
使用全视野视觉刺激在17名受试者中诱发水平OKN反应。记录并分析眼动以确定受试者能够维持OKN反应的最大刺激速度(V(max))。将该终点与logMAR VA和戈德曼视野(VF)测试结果进行比较。
V(max)取决于VA、VF和刺激的空间频率(SF),得出方程V(max)=14.2·log(VA)-6.20·log(SF)+0.22·VF+25.0。研究结果表明,在全视野OKN刺激下的V(max)可能提供VA和周边视力的客观测量。
对于被视为新视觉康复策略候选者的特定严重视力受损患者群体,OKN测试作为评估视觉功能的一种额外的、更客观的方法可能有用。