Gräf M
Universitäts-Augenklinik für Schielbehandlung und Neuroophthalmologie Giessen.
Klin Monbl Augenheilkd. 1998 Apr;212(4):196-202. doi: 10.1055/s-2008-1034864.
To develop and to validate an objective method which allows an estimation of the visual acuity (VA) of adults.
A horizontal optokinetic nystagmus (OKN) was elicited by a vertical rectangular grating presented on a PC-screen and was recorded by an infrared reflection method. Superimposition of three stationary black detection stimuli was used to suppress the OKN. The size of these stimuli was increased every two seconds, in ten steps. Suppression of the OKN was taken as an indication that the stimuli were detected. The relation between the smallest effective stimulus and logVA was evaluated in 65 healthy volunteers (130 eyes) with artificially reduced VA and 425 cooperative patients (842 eyes) whose VA was reduced due to different etiologies. The tolerance intervals of logVA related to the discrete detection stimuli were calculated.
The method allows an estimation of the least expectable VA in steps of 0.8, 0.32, 0.25, 0.12, 0.1, 0.06, 0.03 und 0.025 due to the smallest value of three trials. The least VA of strabismic amblyopic eyes can only be estimated in steps of 0.16, 0.06, and 0.02. A VA > 0.02 can be proven with high reliability.
The method allows a clinically useful, objective estimation of the least VA without observer bias in non-amblyopic eyes.
开发并验证一种可用于估计成年人视力(VA)的客观方法。
通过在电脑屏幕上呈现垂直矩形光栅诱发水平视动性眼震(OKN),并用红外反射法进行记录。使用三个静止的黑色检测刺激物叠加来抑制OKN。这些刺激物的大小每两秒增加一次,共十步。OKN的抑制被视为刺激物被检测到的标志。在65名视力人工降低的健康志愿者(130只眼)和425名因不同病因导致视力降低的合作患者(842只眼)中评估最小有效刺激与对数视力之间的关系。计算与离散检测刺激相关的对数视力的耐受区间。
该方法可根据三次试验中的最小值,以0.8、0.32、0.25、0.12、0.1、0.06、0.03和0.025的步长估计最低预期视力。斜视性弱视眼的最低视力只能以0.16、0.06和0.02的步长估计。视力>0.02可得到高度可靠的证明。
该方法可在临床上对非弱视眼的最低视力进行有用的客观估计,且无观察者偏差。