室内变电站作为住宅极低频磁场暴露的预测指标。

Indoor transformer stations as predictors of residential ELF magnetic field exposure.

作者信息

Ilonen K, Markkanen A, Mezei G, Juutilainen Jukka

机构信息

Department of Environmental Science, University of Kuopio, Kuopio, Finland.

出版信息

Bioelectromagnetics. 2008 Apr;29(3):213-8. doi: 10.1002/bem.20385.

Abstract

Transformer stations in apartment buildings may offer a possibility to conduct epidemiological studies that involve high exposure to extremely low frequency magnetic fields (MF), avoid selection bias and minimize confounding factors. To validate exposure assessment based on transformer stations, measurements were performed in thirty buildings in three Finnish cities. In each building, spot measurements in all rooms and a 24-h recording in a bedroom were performed in one apartment above a transformer station (AAT), in one first floor (FF) reference apartment, and one reference apartment on upper floors (UF). The apartment mean of spot measurements was 0.62 microT in the AATs, 0.21 microT in the FF and 0.11 microT in the UF reference apartments The 24-h apartment mean (estimated from the spot measurements and the bedroom 24-h recording) was 0.2 microT or higher in 29 (97%) AATs, in 7 (25%) FF and in 3 (10 %) UF reference apartments. The corresponding numbers for the 0.4 microT cut-off point were 19 (63%), 4 (14%), and 1 (3.3%). The higher MF level in the FF reference apartments indicates that they should not be considered "unexposed" in epidemiological studies. If such apartments are excluded, a transformer station under the floor predicts 24-h apartment mean MF with a sensitivity of 0.41 (or 0.58) and a specificity of 0.997 (or 0.97), depending on the MF cut-off point (0.2 or 0.4 microT). The results indicate that apartments can be reliably classified as high and low MF field categories based on the known location of transformer stations.

摘要

公寓楼中的变电站可能为开展涉及高暴露于极低频磁场(MF)的流行病学研究提供了一种可能性,可避免选择偏倚并将混杂因素降至最低。为验证基于变电站的暴露评估,在芬兰三个城市的30栋建筑物中进行了测量。在每栋建筑物中,对位于变电站上方的一套公寓(AAT)、一套一楼(FF)参考公寓和一套较高楼层(UF)参考公寓的所有房间进行了现场测量,并在其中一套公寓的卧室进行了24小时记录。AAT公寓现场测量的平均值为0.62微特斯拉,FF公寓为0.21微特斯拉,UF参考公寓为0.11微特斯拉。24小时公寓平均值(根据现场测量和卧室24小时记录估算)在29套(97%)AAT公寓中为0.2微特斯拉或更高,在7套(25%)FF公寓和3套(10%)UF参考公寓中也是如此。对于0.4微特斯拉的临界值,相应的数字分别为19套(63%)、4套(14%)和1套(3.3%)。FF参考公寓中较高的MF水平表明,在流行病学研究中不应将其视为“未暴露”。如果排除这些公寓,根据MF临界值(0.2或0.4微特斯拉),地板下的变电站预测24小时公寓平均MF的灵敏度为0.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验