de Veij Marleen, Deneckere Annelien, Vandenabeele Peter, de Kaste Dries, Moens Luc
Ghent University, Laboratory of Analytical Chemistry, Proeftuinstraat 86, B-9000 Ghent, Belgium.
J Pharm Biomed Anal. 2008 Jan 22;46(2):303-9. doi: 10.1016/j.jpba.2007.10.021. Epub 2007 Oct 23.
During the last few years, counterfeiters have become increasingly sophisticated by falsifying drugs and making them look identical to genuine tablets. In this paper, Raman spectroscopy is proposed as a fast and reliable method for the detection of counterfeit Viagra tablets. This technique can easily differentiate genuine from counterfeit tablets without the need of sample preparation. In total 18 tablets were analysed which all contained the active ingredient sildenafil, but different excipients were used, as could be observed in the Raman spectra between 1150 and 700 cm(-1). So, the spectra could be divided into genuine or counterfeit. Additionally, principal component analysis (PCA), combined with hierarchical cluster analysis (HCA), was used to establish an automated approach for the discrimination of counterfeit from genuine Viagra tablets. Raman spectroscopy, combined with principal components analysis, could be used in the future by customs or in the field to identify counterfeit tablets on the spot without involvement of trained chemists.
在过去几年中,造假者通过伪造药品使其外观与正品药片无异,手段越来越高明。本文提出拉曼光谱法作为一种快速可靠的检测假冒伟哥药片的方法。该技术无需样品制备就能轻松区分正品和假冒药片。总共分析了18片药片,所有药片都含有活性成分西地那非,但使用了不同的辅料,这在1150至700厘米(-1)的拉曼光谱中可以观察到。因此,光谱可分为正品或假冒品。此外,主成分分析(PCA)与层次聚类分析(HCA)相结合,用于建立一种自动方法来区分假冒伟哥药片和正品。拉曼光谱法与主成分分析相结合,未来海关或现场可使用该方法在无需专业化学家参与的情况下当场识别假冒药片。