Suppr超能文献

[用于肱骨骨折的长型电报钉]

[The long Telegraph nail for humeral fractures].

作者信息

Cuny C, Irrazi M, Ionescu N, Locquet V, Chaumont P-L, Berrichi A, Wenger V

机构信息

Service de Chirurgie Orthopédique et Traumatologique, CHR de Metz, hôpital Bon-Secours, 1, place de Vigneulles, 57038 Metz Cedex.

出版信息

Rev Chir Orthop Reparatrice Appar Mot. 2007 Oct;93(6):564-70. doi: 10.1016/s0035-1040(07)92678-1.

Abstract

PURPOSE OF THE STUDY

We present an anterograde nailing system for humeral shaft fractures: the long Telegraph(R) nail. This nail enables static or dynamic anteroposterior distal locking and is easy to insert with the special aiming device.

MATERIAL AND METHOD

This study concerned 148 patients who underwent surgery between September 1998 and February 2005, 86 women, men age 68 years and 62 men, mean age 53 years. After excluding patients lost to follow-up and pathological fractures, we analyzed 104 files to determine the rate of nonunion as a function of distal locking or not and dynamic versus static locking. We also reviewed 56 patients measuring the Constant score at mean 2.7 years follow-up.

RESULTS

There were no cases of iatrogenic radial palsy and no cases of infection. There were four cases of nail fracture. The overall rate of nonunion was 7.7%. Nonunion was never observed with dynamic distal locking (p=0.03). Regarding the effect of the nail on shoulder function, the mean weighted Constant score was 105.4% with preservation of mean joint motion and a pain free shoulder in 36/56 patients.

DISCUSSION

The long Telegraph(R) nail enables anterograde nailing of the humeral shaft with a simplified system for dynamic or static distal locking. In this series, dynamic distal locking appeared to provide the best rate of nonunion. If installed correctly, the system does not appear to affect shoulder function.

摘要

研究目的

我们介绍一种用于肱骨干骨折的顺行髓内钉系统:长Telegraph(R)钉。该髓内钉可实现静态或动态的前后位远端锁定,并且借助特殊的瞄准装置易于插入。

材料与方法

本研究纳入了1998年9月至2005年2月期间接受手术的148例患者,其中女性86例,年龄68岁,男性62例,平均年龄53岁。在排除失访患者和病理性骨折患者后,我们分析了104份病例资料,以确定不愈合率与远端锁定与否以及动态锁定与静态锁定之间的关系。我们还对56例患者进行了回顾,在平均随访2.7年时测量Constant评分。

结果

未发生医源性桡神经麻痹病例,也无感染病例。有4例髓内钉断裂。总体不愈合率为7.7%。动态远端锁定从未出现不愈合情况(p = 0.03)。关于髓内钉对肩部功能的影响,平均加权Constant评分为105.4%,56例患者中有36例平均关节活动得以保留且肩部无痛。

讨论

长Telegraph(R)钉可通过一种简化的系统对肱骨干进行顺行髓内钉固定,实现动态或静态的远端锁定。在本系列研究中,动态远端锁定似乎能提供最佳的不愈合率。如果安装正确,该系统似乎不会影响肩部功能。