Suppr超能文献

用于显示手指A2滑车的最佳3T磁共振成像:T1加权、脂肪饱和T2加权和钆增强脂肪饱和T1加权序列之间的比较

Optimal 3-T MRI for depiction of the finger A2 pulley: comparison between T1-weighted, fat-saturated T2-weighted and gadolinium-enhanced fat-saturated T1-weighted sequences.

作者信息

Goncalves-Matoso Vasco, Guntern Daniel, Gray Anne, Schnyder Pierre, Picht Carmen, Theumann Nicolas

机构信息

Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, rue du Bugnon 46, 1011 Lausanne, Switzerland.

出版信息

Skeletal Radiol. 2008 Apr;37(4):307-12. doi: 10.1007/s00256-007-0426-z. Epub 2007 Dec 19.

Abstract

OBJECTIVE

To compare three spin-echo sequences, transverse T1-weighted (T1WI), transverse fat-saturated (FS) T2-weighted (T2WI), and transverse gadolinium-enhanced (Gd) FS T1WI, for the visualisation of normal and abnormal finger A2 pulley with magnetic resonance (MR) imaging at 3 tesla (T).

MATERIALS AND METHODS

Sixty-three fingers from 21 patients were consecutively investigated. Two musculoskeletal radiologists retrospectively compared all sequences to assess the visibility of normal and abnormal A2 pulleys and the presence of motion or ghost artefacts.

RESULTS

Normal and abnormal A2 pulleys were visible in 94% (59/63) and 95% (60/63) on T1WI sequences, in 63% (40/63) and 60% (38/63) on FS T2WI sequences, and in 87% (55/63) and 73% (46/63) on Gd FS T1WI sequences when read by the first and second observer, respectively. Motion and ghost artefacts were higher on FS T2WI sequences. Seven among eight abnormal A2 pulleys were detected, and were best depicted with Gd FS T1WI sequences in 71% (5/7) and 86% (6/7) by the first and the second observer, respectively.

CONCLUSION

In 3-T MRI, the comparison between transverse T1WI, FS T2WI, and Gd FS T1WI sequences shows that transverse T1WI allows excellent depiction of the A2 pulley, that FS T2WI suffers from a higher rate of motion and ghost artefacts, and transverse Gd FS T1WI is the best sequence for the depiction of abnormal A2 pulley.

摘要

目的

比较三种自旋回波序列,即横轴位T1加权(T1WI)、横轴位脂肪抑制(FS)T2加权(T2WI)和横轴位钆增强(Gd)FS T1WI,用于在3特斯拉(T)场强下通过磁共振(MR)成像观察正常和异常手指A2滑车。

材料与方法

对21例患者的63根手指进行连续研究。两名肌肉骨骼放射科医生回顾性比较所有序列,以评估正常和异常A2滑车的可视性以及运动或鬼影伪影的存在情况。

结果

在T1WI序列上,正常和异常A2滑车的可视率分别为94%(59/63)和95%(60/63);在FS T2WI序列上,分别为63%(40/63)和60%(38/63);在Gd FS T1WI序列上,第一位观察者和第二位观察者分别为87%(55/63)和73%(46/63)。FS T2WI序列上的运动和鬼影伪影更多。8个异常A2滑车中有7个被检测到,第一位观察者和第二位观察者分别在71%(5/7)和86%(6/7)的情况下,Gd FS T1WI序列对其显示最佳。

结论

在3T磁共振成像中,横轴位T1WI、FS T2WI和Gd FS T1WI序列的比较表明,横轴位T1WI能很好地显示A2滑车,FS T2WI存在较高的运动和鬼影伪影率,横轴位Gd FS T1WI是显示异常A2滑车的最佳序列。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验