Suppr超能文献

在捏握姿势下评估手指A3滑车破裂——一项磁共振成像尸体研究

Evaluation of finger A3 pulley rupture in the crimp grip position-a magnetic resonance imaging cadaver study.

作者信息

Bayer Thomas, Adler Werner, Schweizer Andreas, Schöffl Isabelle, Uder Michael, Janka Rolf

机构信息

Department of Radiology, University of Erlangen-Nuremberg, Maximiliansplatz 1, 91054, Erlangen, Germany,

出版信息

Skeletal Radiol. 2015 Sep;44(9):1279-85. doi: 10.1007/s00256-015-2160-2. Epub 2015 May 2.

Abstract

PURPOSE

The correct diagnosis of an A3 pulley rupture is challenging for musculoskeletal radiologists. An A3 pulley rupture should in theory influence the shape of the proximal interphalangeal joint volar plate (VP) and the amount of bowstringing at level of the VP during finger flexion. The purpose of this study was to perform MRI with metric analysis of the VP configuration and VP bowstringing in cadaver fingers in the crimp grip position and to determine cut points for A3 pulley rupture.

MATERIALS AND METHODS

MRI in the crimp grip position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (fingers with A3 pulley rupture n = 16, fingers without A3 pulley rupture n = 5). The distances of the translation of the VP relative to the middle phalanx base, the distances between the flexor tendons and the VP body, and the distances between the flexor tendon and bone (TB) were measured.

RESULTS

Statistical analysis showed significantly lower VP translation distances and significantly higher VP tendon distances if the A3 pulley was ruptured. A2 TB and A4 TB distances did not differ significantly in specimens with and without A3 pulley rupture. The optimal cut points for A3 pulley rupture were a VP translation distance <2.8 mm and a VP tendon distance >1.4 mm.

CONCLUSION

Reduction of the VP translation distance and augmentation of the VP tendon distance are suitable indirect signs of A3 pulley rupture.

摘要

目的

对于肌肉骨骼放射科医生而言,正确诊断A3滑车破裂具有挑战性。理论上,A3滑车破裂会影响近端指间关节掌侧板(VP)的形状以及手指屈曲时VP水平的弓弦化程度。本研究的目的是在尸体手指处于紧握位置时进行MRI,并对VP形态和VP弓弦化进行测量分析,以确定A3滑车破裂的切点。

材料与方法

对21根有人为造成的屈肌腱滑车撕裂的尸体手指进行紧握位置的MRI检查(A3滑车破裂的手指n = 16,无A3滑车破裂的手指n = 5)。测量VP相对于中节指骨基部的平移距离、屈肌腱与VP主体之间的距离以及屈肌腱与骨(TB)之间的距离。

结果

统计分析表明,如果A3滑车破裂,VP平移距离显著降低,VP肌腱距离显著增加。有和没有A3滑车破裂的标本中,A2 TB和A4 TB距离无显著差异。A3滑车破裂的最佳切点是VP平移距离<2.8毫米和VP肌腱距离>1.4毫米。

结论

VP平移距离减小和VP肌腱距离增大是A3滑车破裂合适的间接征象。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验