Naeije M, Hansson T L
Department of Masticatory Function, Academic Centre for Dentistry, Amsterdam.
J Craniomandib Disord. 1991 Fall;5(4):245-50.
The short-term effect (4 to 6 weeks) of a stabilization appliance on masticatory muscle activity was investigated in 26 myogenous craniomandibular disorder patients. The patients were instructed to clench at 10% and 50% of their maximum clenching effort in the intercuspal position and on the appliance. Recordings were made before and immediately after appliance delivery, and 2 and 4 weeks after delivery. The average EMG activity of the masseter muscles remained the same during the period of appliance use, whereas the anterior temporal muscles showed an immediate and long-lasting reduction in activity. The appliance also resulted in an improvement in the balance of left and right masseter muscle activity. There was a minor improvement in temporal muscle symmetry at the 50% clenching level and after 4 weeks of appliance use.
对26名肌源性颅下颌关节紊乱患者研究了稳定矫治器对咀嚼肌活动的短期影响(4至6周)。患者被要求在牙尖交错位和佩戴矫治器时,分别以最大紧咬力的10%和50%进行紧咬。在矫治器交付前、交付后即刻以及交付后2周和4周进行记录。在使用矫治器期间,咬肌的平均肌电图活动保持不变,而颞前肌的活动则立即出现并持续降低。该矫治器还使左右咬肌活动的平衡得到改善。在50%紧咬水平以及使用矫治器4周后,颞肌对称性有轻微改善。