There is an ongoing need for field-deployable biosensor devices. We have constructed a fully self-contained, hand-held biosensor, based on the surface plasmon resonance technique. The dimensions of the sensor unit are 15 x 8 cm, the weight is 600 g and it is powered by a 9 V battery. We have characterised the responsiveness of the sensor using calibrated sucrose solutions and were able to measure changes as small as 3.3 x 10(-6) refractive index units. To demonstrate functionality of the sensor, we have prepared surfaces with an antibody fragment specific for the biological toxin ricin. We were able to detect ricin at 200 ng/mL in 10 min, which is approximately 2500 times less than the minimum lethal dose. We were also able to verify positive binding within a second 10 min window. This sensor demonstrates important steps required for the development of fully integrated, hand-held sensor devices and will form the basis of a multi-analyte system, to be developed in the near future. It also represents the first completely hand-held SPR device, not requiring external power or a computer connection to operate.

摘要

对可现场部署的生物传感器设备一直存在需求。我们基于表面等离子体共振技术构建了一种完全独立的手持式生物传感器。传感器单元的尺寸为15×8厘米,重量为600克,由9伏电池供电。我们使用校准的蔗糖溶液对传感器的响应性进行了表征,能够测量低至3.3×10⁻⁶折射率单位的变化。为了证明传感器的功能,我们制备了针对生物毒素蓖麻毒素的抗体片段表面。我们能够在10分钟内检测到浓度为200纳克/毫升的蓖麻毒素,这比最小致死剂量低约2500倍。我们还能够在第二个10分钟窗口内验证阳性结合。该传感器展示了开发完全集成的手持式传感器设备所需的重要步骤,并将成为未来不久开发的多分析物系统的基础。它也是首个完全手持式SPR设备,无需外部电源或计算机连接即可运行。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验