Abstract

OBJECTIVE

To assess the accuracy of a commercially available real-time reverse-transcription-polymerase chain reaction assay for mammaglobin and cytokeratin 19 mRNAs [GeneSearch Breast Lymph Node (BLN) Assay, Veridex LLC, Warren, NJ] in the detection of axillary sentinel lymph nodes (SLNs) metastases in patients with breast carcinoma.

SUMMARY BACKGROUND DATA

Because of the lack of standardized and widely accepted protocols for a truly accurate histopathologic examination of SLN, the relative merits of alternative assays based on the identification of tumor specific mRNA markers deserve further assessment.

METHODS

: A prospective series of 293 consecutive SLNs from 293 patients was evaluated. The BLN assay results were compared with those of an extensive histopathologic examination of the entire SLNs performed on serial frozen sections cut at 40 to 50 microm intervals.

RESULTS

The BLN assay correctly identified 51 of 52 macrometastatic and 5 of 20 micrometastatic SLNs, with a sensitivity of 98.1% to detect metastases larger than 2 mm, 94.7% for metastases larger than 1 mm, and 77.8% for metastases larger than 0.2 mm. The overall concordance with histopathology was 90.8%, with specificity of 95.0%, positive predictive value of 83.6%, and negative predictive value of 92.9%. When the results were evaluated according to the occurrence of additional metastases to non-SLN in patients with histologically positive SLNs, the assay was positive in 33 (91.7%) of the 36 patients with additional metastases and in 22 (66.6%) of the 33 patients without further echelon involvement.

CONCLUSIONS

The sensitivity of the reverse-transcription -polymerase chain reaction assay is comparable to that of the histopathologic examination of the entire SLN by serial sectioning at 1.5 to 2 mm.

摘要

目的

评估一种市售的用于检测乳腺珠蛋白和细胞角蛋白19信使核糖核酸的实时逆转录-聚合酶链反应检测法[基因搜索乳腺淋巴结(BLN)检测法,Veridex有限责任公司,新泽西州沃伦市]在检测乳腺癌患者腋窝前哨淋巴结(SLN)转移方面的准确性。

总结背景数据

由于缺乏用于对SLN进行真正准确的组织病理学检查的标准化且被广泛接受的方案,基于肿瘤特异性信使核糖核酸标志物识别的替代检测法的相对优点值得进一步评估。

方法

对来自293例患者的293个连续的SLN进行前瞻性系列评估。将BLN检测结果与对整个SLN进行的广泛组织病理学检查结果进行比较,该检查是在以40至50微米间隔切割的系列冰冻切片上进行的。

结果

BLN检测法正确识别出52个大转移灶中的51个以及20个微转移灶中的5个,对于检测大于2毫米的转移灶,灵敏度为98.1%;对于大于1毫米的转移灶,灵敏度为94.7%;对于大于0.2毫米的转移灶,灵敏度为77.8%。与组织病理学的总体一致性为90.8%,特异性为95.0%,阳性预测值为83.6%,阴性预测值为92.9%。当根据组织学阳性SLN患者中非SLN出现额外转移的情况评估结果时,在36例有额外转移的患者中有33例(91.7%)检测为阳性,在33例无进一步梯队受累的患者中有22例(66.6%)检测为阳性。

结论

逆转录-聚合酶链反应检测法的灵敏度与通过以1.5至2毫米间隔连续切片对整个SLN进行组织病理学检查的灵敏度相当。