用于量化桡尺远侧关节平移的各种计算机断层扫描方法的可靠性和正常值。

Reliability and normal values of various computed tomography methods for quantifying distal radioulnar joint translation.

作者信息

Park Min Jong, Kim Jong Pil

机构信息

Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, Seoul 135-710, South Korea.

出版信息

J Bone Joint Surg Am. 2008 Jan;90(1):145-53. doi: 10.2106/JBJS.F.01603.

Abstract

BACKGROUND

Several techniques have been proposed to measure translation of the distal radioulnar joint on computed tomography scans, but the criteria for diagnosing abnormal subluxation have not been standardized. The aims of this study were to evaluate the reliability of the current methods and to derive normal population values with these methods.

METHODS

Computed tomography scans of forty-five asymptomatic wrists were performed with the hand in supination, neutral, and pronation. Four methods for diagnosing subluxation of the distal radioulnar joint were used: the radioulnar line method; the epicenter method; the radioulnar ratio method; and the subluxation ratio method, which is a modification of the radioulnar line method that involves use of a line perpendicular to the sigmoid notch. Three observers measured all of the scans independently and repeated the measurements three months later to determine the interobserver and intraobserver reliability. All of the measurements for each subject were averaged, and the average was considered to be the normal value for that subject.

RESULTS

Interobserver reliability was best (substantial to almost perfect) with use of the subluxation ratio method. The intraclass correlation coefficients showed substantial to almost perfect reliability of the radioulnar line method, substantial reliability of the radioulnar ratio method, and moderate to substantial reliability of the epicenter method. The intraobserver reliability of all methods was almost perfect. The radioulnar line and subluxation ratio methods always showed the ulnar head to be located outside of the dorsal line in pronation and outside of the volar line in supination. The normal epicenter values indicated that the center of rotation of the distal radioulnar joint fell in the middle half of the sigmoid notch in all positions. The normal ranges derived with the radioulnar ratio method demonstrated larger variation than originally reported.

CONCLUSIONS

This study suggests that the subluxation ratio method is the most useful technique for measuring translation of the distal radioulnar joint as a result of its reliability and simplicity. Substantial variations in normal values derived with the current methods should be considered in a computed tomography evaluation of the distal radioulnar joint in symptomatic patients.

摘要

背景

已经提出了几种在计算机断层扫描上测量桡尺远侧关节平移的技术,但诊断异常半脱位的标准尚未标准化。本研究的目的是评估当前方法的可靠性,并使用这些方法得出正常人群的值。

方法

对45个无症状手腕进行计算机断层扫描,手部处于旋前、中立和旋后位。使用四种诊断桡尺远侧关节半脱位的方法:桡尺线法;中心点法;桡尺比法;以及半脱位比法,它是桡尺线法的一种改进,涉及使用一条垂直于乙状切迹的线。三名观察者独立测量所有扫描图像,并在三个月后重复测量以确定观察者间和观察者内的可靠性。对每个受试者的所有测量值进行平均,并将平均值视为该受试者的正常值。

结果

使用半脱位比法时观察者间可靠性最佳(高度一致至几乎完美)。组内相关系数显示桡尺线法具有高度一致至几乎完美的可靠性,桡尺比法具有高度可靠性,中心点法具有中度至高度可靠性。所有方法的观察者内可靠性几乎完美。桡尺线法和半脱位比法始终显示在旋前时尺骨头位于背侧线外侧,在旋后时位于掌侧线外侧。正常中心点值表明,在所有位置,桡尺远侧关节的旋转中心都落在乙状切迹的中间一半。用桡尺比法得出的正常范围显示出比最初报告的更大的变异性。

结论

本研究表明,半脱位比法因其可靠性和简单性,是测量桡尺远侧关节平移最有用的技术。在对有症状患者的桡尺远侧关节进行计算机断层扫描评估时,应考虑使用当前方法得出的正常值存在的显著差异。