Suppr超能文献

通过直接水相进样-气相色谱/质谱联用同时定量分析水样中的极性和非极性挥发性有机化合物。

Simultaneous quantification of polar and non-polar volatile organic compounds in water samples by direct aqueous injection-gas chromatography/mass spectrometry.

作者信息

Aeppli Christoph, Berg Michael, Hofstetter Thomas B, Kipfer Rolf, Schwarzenbach René P

机构信息

Eawag, Swiss Federal Institute of Aquatic Science and Technology, 8600 Dübendorf, Switzerland.

出版信息

J Chromatogr A. 2008 Feb 15;1181(1-2):116-24. doi: 10.1016/j.chroma.2007.12.043. Epub 2007 Dec 23.

Abstract

A direct aqueous injection-gas chromatography/mass spectrometry (DAI-GC/MS) method for trace analysis of 24 volatile organic compounds (VOCs) in water samples is presented. The method allows for the simultaneous quantification of benzene, toluene, ethyl benzene, and xylenes (BTEX), methyl tert-butyl ether (MTBE), tert-butyl alcohol (TBA), as well as a variety of chlorinated methanes, ethanes, propane, enthenes and benzenes. Applying a liquid film polyethylene glycol or a porous layer open tubular (PLOT) divinylbenzene GC capillary column to separate the water from the VOCs, volumes of 1-10 microL aqueous sample are directly injected into the GC. No enrichment or pretreatment steps are required and sample volumes as low as 100 microL are sufficient for accurate quantification. Method detection limits determined in natural groundwater samples were between 0.07 and 2.8 microg/L and instrument detection limits of <5 pg were achieved for 21 out of the 24 evaluated VOCs. DAI-GC/MS offers both good accuracy and precision (relative standard deviations <or=10%). The versatility of our method is demonstrated for contaminant quantification in drinking water disinfection (advanced oxidation of MTBE) and for VOC concentration measurements in a polluted aquifer. The wide range of detectable compounds and the lack of labor-intensive sample preparation illustrate that the DAI method is robust and easily applicable for the quantification of important organic groundwater contaminants.

摘要

本文介绍了一种用于水样中24种挥发性有机化合物(VOCs)痕量分析的直接水相注射-气相色谱/质谱联用(DAI-GC/MS)方法。该方法可同时定量分析苯、甲苯、乙苯和二甲苯(BTEX)、甲基叔丁基醚(MTBE)、叔丁醇(TBA)以及多种氯代甲烷、乙烷、丙烷、乙烯和苯。采用液膜聚乙二醇或多孔层开管(PLOT)二乙烯基苯气相色谱毛细管柱将水与VOCs分离,将1-10微升的水样直接注入气相色谱仪。无需富集或预处理步骤,低至100微升的样品体积就足以进行准确的定量分析。在天然地下水样品中测定的方法检测限在0.07至2.8微克/升之间,24种评估的VOCs中有21种的仪器检测限低于5皮克。DAI-GC/MS具有良好的准确度和精密度(相对标准偏差≤10%)。我们的方法的通用性体现在饮用水消毒中污染物的定量分析(MTBE的高级氧化)以及污染含水层中VOC浓度的测量。可检测化合物范围广且无需进行劳动强度大的样品制备,这表明DAI方法稳健且易于应用于重要的地下水中有机污染物的定量分析。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验