Théron J, Paugam J P, Courthéoux P
Optiray Laboratoire Guerbet, Aulnay-sous-Bois.
Ann Radiol (Paris). 1991;34(6-7):413-7.
A single, open trial was conducted in 40 patients to evaluate the diagnostic efficacy and safety, in cranial computed tomography, of ioversol (350 mgl/ml), a new nonionic, monomeric, low-osmolality contrast medium. Ioversol is characterized by a hydrophilicity which is not only the highest of all nonionic agents available to date, but also evenly distributed among the various sides of the benzene ring. Diagnosis was possible in 100% of cases with a mean degree of certainty of 90.8%. Six minor adverse reactions requiring no treatment were recorded, of which two were observed by the investigator and four reported by the patients. No pain sensation was found and heat sensations were of minor intensity. Ioversol 350, which showed good diagnostic efficacy and proved to be well tolerated, is therefore suitable for cranial computed tomography at a mean dose of 1 ml/kg.
对40例患者进行了一项单组开放性试验,以评估新型非离子单体低渗造影剂碘海醇(350mgl/ml)在头颅计算机断层扫描中的诊断效能和安全性。碘海醇的特点是亲水性不仅是目前所有非离子型造影剂中最高的,而且在苯环的各个侧链上均匀分布。100%的病例均可做出诊断,平均确定度为90.8%。记录到6例无需治疗的轻微不良反应,其中2例由研究者观察到,4例由患者报告。未发现疼痛感觉,热感程度较轻。因此,碘海醇350显示出良好的诊断效能且耐受性良好,平均剂量为1ml/kg时适用于头颅计算机断层扫描。