Suppr超能文献

抗CD3单克隆抗体的荧光素缀合物对人αβ和γδ T细胞的鉴别染色。

Differential staining of human alpha beta and gamma delta T cells by the fluorescein conjugate of an anti-CD3 monoclonal antibody.

作者信息

Mullersman J E, White G, Tung K S

机构信息

Department of Pathology, Washington University School of Medicine, St. Louis, MO 63110.

出版信息

Clin Exp Immunol. 1991 May;84(2):324-8. doi: 10.1111/j.1365-2249.1991.tb08168.x.

Abstract

The enumeration of total T cells, an important function of the clinical immunology laboratory, utilizes antibodies to CD3, the macromolecular complex associated with the antigen-specific receptors of T cells. We compared the ability of some commonly employed commercial anti-CD3 reagents to stain human peripheral blood lymphocytes. Surprisingly, the fluorescein isothiocyanate (FITC) conjugate of Coulter clone T3 (FITC-T3) stained most T cells brightly, but selectively stained gamma delta T cells very dimly or not at all. In contrast, the other anti-CD3 reagents studied (FITC-Leu 4, PE-T3, PE-Leu 4, and indirectly labelled T3 and Leu 4) stained all T cells equivalently. Dual-colour flow cytometric analysis with FITC-T3 and PE-Leu 4 readily demonstrated a FITC-T3-/PE-Leu 4+ population of T cells. This unique population stained dimly or not at all with a combination of anti-CD4 and anti-CD8 monoclonal antibodies and positively with the pan-gamma delta T cell antibody TCR delta 1. Moreover, an excellent correlation was found between the number of FITC-T3-/PE-Leu 4+ cells and the number of TCR delta 1+ cells in 32 normal individuals. Thus, the FITC-T3-/PE-Leu 4+ phenotype accurately marks all gamma delta T cells. In contrast to FITC-T3, both PE-conjugated and unconjugated T3 stained gamma delta T cells brightly. Therefore, T3 binds to an epitope present on all T cells, but fluoresceinylation specifically attenuates this antibody's ability to bind to gamma delta T cells. These findings indicate that the use of FITC-T3 can result in a significant and variable underestimation of peripheral blood T cell number and demonstrate further that the CD3 complexes of human alpha beta and gamma delta T cells are significantly different.

摘要

总T细胞计数是临床免疫实验室的一项重要功能,它利用针对CD3的抗体,CD3是与T细胞抗原特异性受体相关的大分子复合物。我们比较了一些常用的商业抗CD3试剂对人外周血淋巴细胞染色的能力。令人惊讶的是,库尔特克隆T3的异硫氰酸荧光素(FITC)偶联物(FITC-T3)能使大多数T细胞明亮染色,但对γδ T细胞的染色非常暗淡或根本不染色。相比之下,研究的其他抗CD3试剂(FITC-Leu 4、PE-T3、PE-Leu 4以及间接标记的T3和Leu 4)对所有T细胞的染色效果相同。用FITC-T3和PE-Leu 4进行双色流式细胞术分析很容易显示出一群FITC-T3-/PE-Leu 4+的T细胞。这一独特群体用抗CD4和抗CD8单克隆抗体组合染色暗淡或根本不染色,而用泛γδ T细胞抗体TCRδ 1染色呈阳性。此外,在32名正常个体中,发现FITC-T3-/PE-Leu 4+细胞数量与TCRδ 1+细胞数量之间存在极好的相关性。因此,FITC-T3-/PE-Leu 4+表型准确地标记了所有γδ T细胞。与FITC-T3不同,PE偶联的和未偶联的T3都能使γδ T细胞明亮染色。因此,T3能结合所有T细胞上存在的一个表位,但荧光素化会特异性减弱该抗体与γδ T细胞结合的能力。这些发现表明,使用FITC-T3可能会导致外周血T细胞数量显著且可变地被低估,并进一步证明人αβ和γδ T细胞的CD3复合物存在显著差异。

相似文献

本文引用的文献

9
Developmental biology of T cell receptors.T细胞受体的发育生物学
Science. 1989 May 26;244(4907):943-50. doi: 10.1126/science.2658058.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验