Tsurugi Takuo, Abe Haruhiko, Oginosawa Yasushi, Kohno Ritsuko, Yasumasu Tomiya, Nagatomo Toshihisa, Otsuji Yutaka
The Second Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan.
J Cardiovasc Electrophysiol. 2008 Jul;19(7):702-7. doi: 10.1111/j.1540-8167.2008.01109.x. Epub 2008 Feb 13.
We compared, in patients with sick sinus syndrome, the effects of various pacing modes on baroreceptor (BR)-stroke volume (SV) reflex sensitivity, a method we have closely correlated with BR-heart rate (HR) reflex sensitivity.
Impaired autonomic nervous function, such as decreased BR-HR reflex sensitivity, predicts sudden cardiac death. However, in patients with sick sinus syndrome, the effects of various pacing modes on autonomic function are unknown, since chronotropic incompetence precludes its evaluation by measurements of BR-HR reflex sensitivity.
We studied 12 recipients of dual-chamber pacemakers with sick sinus syndrome (mean age = 73 +/- 8 years; 8 men). Beat-by-beat blood pressure (BP) and SV were measured during 5-minute runs of AAI, DDD, and VVI pacing, and spectrally analyzed to assess BR-SV reflex sensitivity.
Systolic BP was significantly lower (P < 0.01) during VVI (109 +/- 24 mmHg) than during DDD (124 +/- 22 mmHg) or AAI (125 +/- 41 mmHg) pacing. SV was significantly smaller during VVI (36 +/- 23 mL) than during DDD (49 +/- 31 mL) pacing (P < 0.05). BR-SV reflex sensitivity was significantly lower (P < 0.05) during VVI (9.3 +/- 5.7% per mmHg) than during DDD (15.0 +/- 6.5% per mmHg) or AAI (15.5 +/- 6.2% per mmHg) pacing.
BR-SV reflex sensitivity was significantly lower during VVI than during AAI or DDD pacing. Atrioventricular synchrony plays an important role in the preservation of BR-SV reflex sensitivity in pacemaker recipients.