Suppr超能文献

12个月内下颌磨牙部位即刻负重种植体与传统负重种植体的住院患者比较。

In-patient comparison of immediate and conventional loaded implants in mandibular molar sites within 12 months.

作者信息

Güncü M Bariş, Aslan Yavuz, Tümer Celal, Güncü Güliz N, Uysal Serdar

机构信息

Department of Prosthodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey.

出版信息

Clin Oral Implants Res. 2008 Apr;19(4):335-41. doi: 10.1111/j.1600-0501.2007.01471.x. Epub 2008 Feb 20.

Abstract

OBJECTIVES

The aim of this prospective clinical study was to evaluate the clinical outcomes of dental implants placed in the mandibular molar sites and immediately functionally restored compared with conventionally loaded controls in an in-patient study.

MATERIAL AND METHODS

Twenty-four dental implants were placed in 12 patients who had first molar loss bilaterally in the mandibular area. One site of the patient was determined as immediately loaded (IL) and the other side was conventionally loaded (CL). Resonance frequency analyses for implant stability measurements, radiographic examinations for marginal bone levels and peri-implant evaluations were performed during the clinical follow-up appointments within 12 months.

RESULTS

During the 12-month follow-up period, only one implant was lost in the IL group. The mean implant stability quotient values were 74.18+/-5.72 and 75.18+/-3.51 for Groups IL and CL at surgery, respectively, and the corresponding values were 75.36+/-5.88 and 75.64+/-4.84 at 1-year recall, respectively. The difference was not statistically significant between the two groups during the 12-month study period (P>0.05). When peri-implant parameters were evaluated, excellent peri-implant health was demonstrated during the 1-year observation period and all implants showed less than 1 mm of marginal bone resorption during the first year.

CONCLUSIONS

In the present study, immediate functionally loading did not negatively affect implant stability, marginal bone levels and peri-implant health when compared with conventional loading of single-tooth implants.

摘要

目的

本前瞻性临床研究旨在评估在下颌磨牙部位植入牙种植体并立即进行功能修复的临床效果,并与住院研究中传统加载的对照组进行比较。

材料与方法

对12例双侧下颌第一磨牙缺失的患者植入24颗牙种植体。将患者的一侧确定为即刻加载(IL),另一侧为传统加载(CL)。在12个月内的临床随访期间,进行种植体稳定性测量的共振频率分析、边缘骨水平的影像学检查和种植体周围评估。

结果

在12个月的随访期内,IL组仅1颗种植体丢失。IL组和CL组在手术时的平均种植体稳定性商值分别为74.18±5.72和75.18±3.51,在1年回访时相应的值分别为75.36±5.88和75.64±4.84。在12个月的研究期间,两组之间的差异无统计学意义(P>0.05)。在评估种植体周围参数时,在1年观察期内种植体周围健康状况良好,所有种植体在第一年的边缘骨吸收均小于1mm。

结论

在本研究中,与单颗牙种植体的传统加载相比,即刻功能加载对种植体稳定性、边缘骨水平和种植体周围健康没有负面影响。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验