用于平面心肌灌注显像的99锝-甲氧基异丁基异腈;不如物理特性理想。

99Tcm-SESTAMIBI for planar myocardial perfusion imaging; not as ideal as the physical properties.

作者信息

Verzijlbergen J F, Cramer M J, Niemeyer M G, Ascoop C A, Van der Wall E E, Pauwels E K

机构信息

Department of Nuclear Medicine, St Antonius Hospital, Nieuwegein, The Netherlands.

出版信息

Nucl Med Commun. 1991 May;12(5):381-91. doi: 10.1097/00006231-199105000-00002.

Abstract

99Tcm-methoxyisobutyl isonitrile (Tc-SESTAMIBI) has recently been introduced as a new myocardial perfusion agent which exhibits ideal physical properties for imaging with the gamma camera. To assess the diagnostic accuracy of planar Tc-SESTAMIBI, myocardial perfusion imaging was performed in 60 consecutive patients at rest and during exercise. The results were compared with coronary angiographic findings, obtained within 3 months of the exercise test. Planar 201Tl images were also performed on the same day and to the same level of stress as the Tc-SESTAMIBI exercise. Exact segmental agreement between Tc-SESTAMIBI and 201Tl was 77%. Nineteen per cent of all 900 segments demonstrated ischaemia with Tc-SESTAMIBI and 20% with 201Tl. The overall sensitivity for detecting haemodynamically significant coronary artery disease with Tc-SESTAMIBI was 86% and specificity was 78%; with 201Tl the values were 89 and 78%, respectively (differences not significant). Vessel-specific comparative detection rates revealed no statistical significant differences between both radiopharmaceuticals. Intra-observer variability for Tc-SESTAMIBI images was 12% and for 201Tl it was 14%. Inter-observer variability for Tc-SESTAMIBI was 14% and for 201Tl 17%. Although the physical characteristics of Tc-SESTAMIBI allow crisp and clear high-count density imaging, no significant differences are found when planar images are compared with 201Tl and are well within observer variabilities.

摘要

99锝-甲氧基异丁基异腈(锝-司他米比)最近作为一种新型心肌灌注剂被引入,它具有适合γ相机成像的理想物理特性。为评估平面锝-司他米比的诊断准确性,对60例连续患者在静息和运动时进行了心肌灌注显像。将结果与运动试验后3个月内获得的冠状动脉造影结果进行比较。同一天还对相同应激水平下的锝-司他米比运动显像进行了平面铊-201显像。锝-司他米比与铊-201之间确切的节段一致性为77%。在所有900个节段中,19%在锝-司他米比显像时显示缺血,20%在铊-201显像时显示缺血。用锝-司他米比检测血流动力学显著冠状动脉疾病的总体敏感性为86%,特异性为78%;用铊-201时,数值分别为89%和78%(差异无统计学意义)。血管特异性比较检测率显示两种放射性药物之间无统计学显著差异。锝-司他米比图像的观察者内变异性为12%,铊-201图像的观察者内变异性为14%。锝-司他米比的观察者间变异性为14%,铊-201的观察者间变异性为17%。尽管锝-司他米比的物理特性允许进行清晰且高计数密度的成像,但与铊-201的平面图像相比未发现显著差异,且均在观察者变异性范围内。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验