Gyatsho Jamyang, Kaushik Sushmita, Gupta Amod, Pandav Surinder Singh, Ram Jagat
Department of Ophthalmology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
J Glaucoma. 2008 Mar;17(2):122-7. doi: 10.1097/IJG.0b013e31814b9817.
To determine retinal nerve fiber layer (RNFL) thickness measurements in normal, ocular hypertensive (OHT), and glaucomatous Asian Indian eyes.
This prospective observational cross-sectional study included patients with OHT, primary open angle glaucoma (POAG), and age-matched normal controls. The global and 4-quadrant average RNFL thickness was measured using the Stratus OCT. The main outcome measures were differences in RNFL thickness measurements between the 3 groups. The discriminating power of each parameter was evaluated by calculating areas under receiver operating characteristic curves (AROCs).
Twenty-three eyes of 23 POAG patients, 24 eyes of 24 OHT, and 48 eyes of 48 normal controls were analyzed. The superior, inferior, and global RNFL measurements were significantly thinner in OHTs compared with normals (P=0.031, 0.019, and 0.022, respectively). All 5 RNFL parameters were significantly thinner in the POAG group compared with OHT group (P<0.001). Parameters with largest AROCs for distinguishing glaucoma from OHT were average and inferior average RNFL measurements (0.989 and 0.979, respectively). Inferior and superior RNFL measurements had largest AROCs (0.717 and 0.700, respectively) to distinguish OHT from normal eyes.
Stratus OCT detected significant quantitative differences in RNFL thickness between normal, OHT, and glaucomatous Asian Indian eyes.
测定正常、高眼压(OHT)和青光眼亚洲印度裔眼睛的视网膜神经纤维层(RNFL)厚度。
这项前瞻性观察性横断面研究纳入了高眼压症患者、原发性开角型青光眼(POAG)患者以及年龄匹配的正常对照者。使用Stratus OCT测量全视网膜和四个象限的平均RNFL厚度。主要观察指标是三组之间RNFL厚度测量值的差异。通过计算受试者操作特征曲线下面积(AROC)评估每个参数的鉴别能力。
分析了23例POAG患者的23只眼、24例高眼压症患者的24只眼和48例正常对照者的48只眼。与正常眼相比,高眼压症患者的上方、下方和全视网膜RNFL测量值显著变薄(分别为P = 0.031、0.019和0.022)。与高眼压症组相比,POAG组的所有5个RNFL参数均显著变薄(P < 0.001)。区分青光眼和高眼压症的AROC最大的参数是平均RNFL测量值和下方平均RNFL测量值(分别为0.989和0.979)。区分高眼压症和正常眼的AROC最大的参数是下方和上方RNFL测量值(分别为0.717和0.700)。
Stratus OCT检测到正常、高眼压和青光眼亚洲印度裔眼睛之间RNFL厚度存在显著的定量差异。