Head computed tomography examinations are often accompanied with unnecessary irradiation of superficial organs that are rarely the main target for the investigation. The aim of this work is to demonstrate that lead shields could be effectively used to protect superficial organs without compromising image quality where superficial organ itself is not a target and that the irradiation of the superficial organ is unavoidable. The objective was achieved by first assessing the image quality using phantom measurements made with and without lead shielding in order to determine optimal shielding thickness for patient applications. The entrance surface doses (ESDs) to superficial organs of sixty patients were measured using LiF-thermoluminescent dosemeters without, with one layer, or with two layers of lead shields. Phantom studies demonstrated that the use of modified lead shields of up to 0.25 mm thickness could be used without significant effect on the image quality for central and posterior regions. In these studies, lead shields of 0.25 mm thickness reduce the ESDs to the lens of the eyes and thyroid by 44 and 51%, respectively. The image quality reduction by eye shields was significant to the anterior (i.e. orbital) region but marginal to the central and posterior regions (cerebrum). In view of the above, the use of modified lead shields could reduce the dose to the superficial organs considerably without significantly compromising image quality.

摘要

头部计算机断层扫描检查常常伴随着对浅表器官的不必要照射,而这些浅表器官很少是检查的主要目标。这项工作的目的是证明,在浅表器官本身不是目标且对其照射不可避免的情况下,铅屏蔽可有效用于保护浅表器官而不影响图像质量。通过首先使用有铅屏蔽和无铅屏蔽的体模测量来评估图像质量,以确定适用于患者的最佳屏蔽厚度,从而实现了这一目标。使用LiF热释光剂量计测量了60例患者在无铅屏蔽、有一层铅屏蔽或有两层铅屏蔽情况下浅表器官的体表入射剂量(ESD)。体模研究表明,使用厚度达0.25毫米的改良铅屏蔽对中央和后部区域的图像质量无显著影响。在这些研究中,0.25毫米厚的铅屏蔽分别使眼部晶状体和甲状腺的ESD降低了44%和51%。眼罩对前部(即眼眶)区域的图像质量降低显著,但对中央和后部区域(大脑)的影响较小。鉴于上述情况,使用改良铅屏蔽可在不显著影响图像质量的情况下,大幅降低对浅表器官的剂量。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验