Gynecol Oncol. 2008 Jul;110(1):22-31. doi: 10.1016/j.ygyno.2008.03.022. Epub 2008 May 16.

Abstract

OBJECTIVE

The aim of our study was to evaluate the accuracy of multidetector computed tomography (MDCT) on a 16-row CT scanner in the detection and differentiation of adnexal masses.

METHODS

We prospectively examined 102 consecutive women with clinically or sonographically detected adnexal masses. Preoperative CT examination was performed, including scanning of the abdomen during the portal phase, using a detector collimation of 16 x 0.75 mm and a pitch of 1.2. Multiplanar reformatted images were evaluated for the presence of an adnexal mass and differentiation between benign and malignant ones, using the surgical and pathologic results as standard of reference. CT findings used to diagnose malignancy were: diameter greater than 4 cm, presence of masses bilaterally, cystic-solid mass, necrosis in a solid lesion, cystic lesion with thick, irregular walls or septa and/or with papillary projections. Presence of ascites, peritoneal metastases and lymphadenopathy was used to confirm malignancy. Multiple logistic regression analysis of the MDCT findings was performed to determine those more predictive of malignancy.

RESULTS

Histopathologic examination demonstrated 143 adnexal mass lesions, 96 (67%) of which were benign and 47 (33%) malignant. Multidetector CT detected 129 (90%) of the 143 adnexal masses, with an overall accuracy for the diagnosis of malignancy of 89.15%. The MDCT findings that found more predictive of malignancy were the presence of papillary projections in a cystic lesion, necrosis in solid mass and peritoneal metastases.

CONCLUSION

Multidetector computed tomography on a 16-row CT scanner proved accurate in the detection and characterization of adnexal masses.

摘要

目的

我们研究的目的是评估16排CT扫描仪上的多排螺旋CT(MDCT)在附件肿块检测和鉴别诊断中的准确性。

方法

我们前瞻性地检查了102例临床上或超声检查发现有附件肿块的连续女性患者。术前进行CT检查,包括门静脉期腹部扫描,探测器准直为16×0.75mm,螺距为1.2。以手术和病理结果作为参考标准,对多平面重组图像进行评估,以确定是否存在附件肿块以及鉴别良性和恶性肿块。用于诊断恶性肿瘤的CT表现为:直径大于4cm、双侧有肿块、囊实性肿块、实性病变内有坏死、囊壁增厚且不规则或有分隔和/或有乳头状突起的囊性病变。腹水、腹膜转移和淋巴结病的存在用于确诊恶性肿瘤。对MDCT表现进行多因素logistic回归分析,以确定那些对恶性肿瘤更具预测性的因素。

结果

组织病理学检查显示143个附件肿块病变,其中96个(67%)为良性,47个(33%)为恶性。多排螺旋CT检测到了143个附件肿块中的129个(90%),诊断恶性肿瘤的总体准确率为89.15%。MDCT表现中对恶性肿瘤更具预测性的是囊性病变中有乳头状突起、实性肿块中有坏死以及腹膜转移。

结论

16排CT扫描仪上的多排螺旋CT在附件肿块的检测和特征描述方面被证明是准确的。