五种功率自行车模型在不同显示功率输出下的耗氧量需求:一项初步研究。

Vo2 requirement at different displayed power outputs on five cycle ergometer models: a preliminary study.

机构信息

Département de Kinésiologie, Université de Montréal, CP 6128, Centreville, Montréal, QC, Canada H3C 3J7.

出版信息

Br J Sports Med. 2010 May;44(6):449-54. doi: 10.1136/bjsm.2007.044826. Epub 2008 Jun 6.

Abstract

BACKGROUND AND AIMS

The validity of five brands of cycle ergometers was evaluated by the comparison of the Vo(2) requirements at different displayed power.

METHODS AND RESULTS

Five physically active men performed a continuous incremental exercise test on five ergometers (Ergomeca, Lifecycle, Monark, Polar S710 and CompuTrainer). The latter was also compared with a standard dynamometer in order to associate Vo(2) values with the real power. Every test started with a 5-min warm-up on the same cycle ergometer (Ergomeca) at 100 W to make sure that the Vo(2) differences do not come from Vo(2) measurement error. Only last minute steady-state Vo(2) values of each 2-min stage were used for the Vo(2)-watt curve. Large differences (5- 10 ml kg(-1) min(-1)) at the same displayed power indicate inaccuracy of displayed power output (PO). Using corrected power values from the dynamometer revealed that for the same Vo(2) the CompuTrainer underestimates PO by approximately 30 W between 100 and 300 W, whereas the Lifecycle overestimate it by 3-53 W from 100 to 300 W. The Monark and Polar S710 underestimate PO by 15 W and the Ergomeca by approximately 5 W.

CONCLUSION

Inaccuracies between -10% and 18% in displayed PO of various cycle ergometers question their interchangeability.

摘要

背景与目的

通过比较不同显示功率下的 VO₂需求,评估了五种品牌的功率自行车的有效性。

方法与结果

五名身体活跃的男性在五种功率自行车(Ergomeca、Lifecycle、Monark、Polar S710 和 CompuTrainer)上进行了连续递增运动测试。为了将 VO₂值与实际功率相关联,还将后一种与标准测力计进行了比较。每个测试都以 100 W 在同一台功率自行车(Ergomeca)上进行 5 分钟的热身,以确保 VO₂差异不是由于 VO₂测量误差引起的。仅使用每个 2 分钟阶段的最后一分钟稳态 VO₂值来绘制 VO₂-瓦特曲线。在相同的显示功率下,较大的差异(5-10 ml·kg⁻¹·min⁻¹)表明显示功率输出(PO)不准确。使用测力计的校正功率值表明,对于相同的 VO₂,CompuTrainer 在 100 至 300 W 之间的 PO 低估了约 30 W,而 Lifecycle 则高估了 3-53 W;Monark 和 Polar S710 低估了 15 W,而 Ergomeca 则低估了大约 5 W。

结论

各种功率自行车的显示 PO 之间存在-10%至 18%的不准确,这质疑了它们的可互换性。