Abstract

Mechanical properties of abdominal and thoracic arteries of 2mm in diameter were determined from adults Wistar rats. A tensile testing instrument was used to obtain stress/strain curves with arteries immersed in physiological buffer at 37 degrees C. A displacement was applied on all arteries with various frequencies (1-7.5Hz) and strains (5-60%). From each curve a Young modulus was obtained using a mathematical model based on a nonlinear soft tissue model. No influence of frequency on modulus was evidenced in the tested range. Abdominal aortas, which were found slightly thicker than thoracic aortas, were characterized by a higher modulus. Due to the interest of decellularized biological materials, we also used SDS/Triton treated arteries, and found that the chemical treatment increased modulus of thoracic arteries. Tensile tests were also performed on thoracic aortas in the longitudinal and transversal directions. Longitudinal moduli were found higher than transversal moduli and the difference could be related to the longitudinal orientation of collagen fibers. These data and mathematical model seem useful in the design of new vascular synthetic or biological prostheses for the field of tissue engineering.

摘要

从成年Wistar大鼠身上测定了直径为2毫米的腹主动脉和胸主动脉的力学性能。使用拉伸测试仪器,在37摄氏度的生理缓冲液中浸泡动脉,以获得应力/应变曲线。对所有动脉施加不同频率(1 - 7.5Hz)和应变(5 - 60%)的位移。利用基于非线性软组织模型的数学模型从每条曲线中获得杨氏模量。在测试范围内未发现频率对模量有影响。发现腹主动脉比胸主动脉略厚,其特征是模量更高。由于对脱细胞生物材料感兴趣,我们还使用了经SDS/ Triton处理的动脉,发现化学处理增加了胸主动脉的模量。还对胸主动脉进行了纵向和横向的拉伸试验。发现纵向模量高于横向模量,这种差异可能与胶原纤维的纵向排列有关。这些数据和数学模型似乎对组织工程领域新型血管合成或生物假体的设计有用。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验