A simple and rapid HPLC method was established for simultaneously determining six active components in Fructus Corni. The six components were separated on an Agilent Zorbax Extend C18 column (250 mmx4.6 mm, 5 microm) and detected by diode array detector (DAD). Mobile phase was composed of (A) aqueous phosphoric acid (0.1%, v/v) and (B) acetonitrile phosphoric acid (0.1%, v/v) using a gradient elution. Analyses were performed at 30 degrees C with a flow rate of 1.0 mL/min and UV detection at 218 nm, 240 nm and 284 nm. All calibration curves showed good linear regression (r2>or=0.9999) within tested ranges. The LOD and LOQ were 0.11-1.69 microg/mL and 1.48-16.60 microg/mL, respectively. Overall intra-day and inter-day variations were less than 4.72%, and the average recoveries were 97.97-102.51% for the analytes. The developed method can be applied to the intrinsic quality control of Fructus Corni.
建立了一种简单快速的高效液相色谱法,用于同时测定山茱萸中的六种活性成分。六种成分在安捷伦Zorbax Extend C18柱(250 mm×4.6 mm,5μm)上分离,并用二极管阵列检测器(DAD)检测。流动相由(A)磷酸水溶液(0.1%,v/v)和(B)乙腈磷酸溶液(0.1%,v/v)组成,采用梯度洗脱。分析在30℃下进行,流速为1.0 mL/min,在218 nm、240 nm和284 nm处进行紫外检测。所有校准曲线在测试范围内均显示出良好的线性回归(r2≥0.9999)。检测限和定量限分别为0.11 - 1.69μg/mL和1.48 - 16.60μg/mL。日内和日间总体变化小于4.72%,分析物的平均回收率为97.97 - 102.51%。所建立的方法可应用于山茱萸的内在质量控制。