Crutchfield C D, Murphy R W, Van Ert M D
School of Health Related Professions, University of Arizona, Tucson 85719.
Am Ind Hyg Assoc J. 1991 Jun;52(6):249-51. doi: 10.1080/15298669191364677.
An automated version of a new method for quantitative respirator fit testing by controlled negative pressure was compared with a computerized aerosol fit test system. The controlled negative pressure technique eliminates many of the problems associated with aerosol and pressure decay fit test methods. A series of fixed leaks was used to compare the leak measurement capabilities of the controlled negative pressure system against a standard computerized aerosol fit test system. Negative pressure and aerosol fit factors determined for a series of fixed leaks through hypodermic needles were highly correlated with each other (r = 0.998) and with the cross-sectional areas of the leak needles (r greater than 0.995).