Tribe L A, Briens C L, Margaritis A
Department of Chemical and Biochemical Engineering, University of Western Ontario, London, Ontario, Canada N6A 5B9.
Biotechnol Bioeng. 1995 May 20;46(4):388-92. doi: 10.1002/bit.260460412.
There are many dynamic methods for measuring the volumetric mass transfer coefficient. The "gas out-gas in" method can directly determine the volumetric mass transfer coefficient in a bioreactor system and provide estimates of the volumetric microbial oxygen uptake rate and the average oxygen saturation concentration at the gas-liquid interface. The errors on these parameters are large if the dissolved oxygen probe response time is not considered. For reliable measurements, deconvolution of the oxygen probe measurements must be made. (c) 1995 John Wiley & Sons, Inc.
有许多用于测量体积传质系数的动态方法。“出气 - 进气”法可以直接测定生物反应器系统中的体积传质系数,并估算体积微生物氧摄取率和气 - 液界面处的平均氧饱和浓度。如果不考虑溶解氧探头的响应时间,这些参数的误差会很大。为了获得可靠的测量结果,必须对氧探头的测量值进行反卷积处理。(c) 1995约翰威立父子公司。