Whitaker J E, Haugland R P, Prendergast F G
Molecular Probes, Inc., Eugene, Oregon 97402.
Anal Biochem. 1991 May 1;194(2):330-44. doi: 10.1016/0003-2697(91)90237-n.
A series of fluorescent, long-wavelength, benzo[c]-xanthene dyes has been characterized for pH measurement in both excitation and emission ratio applications. The two general classes of these indicators are seminaphthofluoresceins (SNAFLs) and seminaphthorhodafluors (SNARFs) which are substituted at the 10-position with oxygen or nitrogen, respectively. These probes show separate emissions from the protonated and deprotonated forms of the fluorophores. The dyes may be excited at 488 or 514 nm with argon ion lasers. Most of the indicators have pKa values between 7.6 and 7.9. Detailed photophysical studies were conducted on the carboxy-SNAFL-1 system and excited-state prototropic reactions were compared to structurally related derivatives, such as the umbelliferones. Membrane permeant esters, such as diacetates and acetoxymethyl esters have also been prepared. The indicators are spectrally well resolved from calcium indicators such as fura-2 and indo-1 and should be suitable for simultaneous determination of pH and Ca2+ transients.
已对一系列用于激发和发射比率应用中pH测量的荧光长波长苯并[c]呫吨染料进行了表征。这些指示剂的两大类是半萘荧光素(SNAFLs)和半萘罗丹明荧光素(SNARFs),它们分别在10位被氧或氮取代。这些探针显示了荧光团质子化和去质子化形式的单独发射。这些染料可用氩离子激光在488或514nm激发。大多数指示剂的pKa值在7.6至7.9之间。对羧基-SNAFL-1系统进行了详细的光物理研究,并将激发态质子转移反应与结构相关的衍生物(如伞形酮)进行了比较。还制备了膜渗透性酯,如二乙酸酯和乙酰氧基甲酯。这些指示剂在光谱上与钙指示剂(如fura-2和indo-1)有很好的分辨,应该适用于同时测定pH和Ca2+瞬变。