Suppr超能文献

使用高分辨率测压法研究咽部吞咽功能。

Investigation of pharyngeal swallowing function using high-resolution manometry.

作者信息

Takasaki Kenji, Umeki Hiroshi, Enatsu Kaori, Tanaka Fujinobu, Sakihama Noriyuki, Kumagami Hidetaka, Takahashi Haruo

机构信息

Department of Otolaryngology-Head and Neck Surgery, Nagasaki University Graduate School of Biomedical Sciences, Sakamoto, Nagasaki, Japan.

出版信息

Laryngoscope. 2008 Oct;118(10):1729-32. doi: 10.1097/MLG.0b013e31817dfd02.

Abstract

OBJECTIVES/HYPOTHESIS: This study aimed to demonstrate the feasibility of a novel high-resolution manometry system, and to establish normal values of swallowing pressures along the velopharynx and upper esophagus.

STUDY DESIGN

Prospective study.

METHODS

Thirty-three asymptomatic adult Japanese controls were studied. A solid-state high-resolution manometry assembly with 36 circumferential sensors spaced 1 cm apart was positioned to record pressures during swallowing from the velopharynx to the upper esophagus. The maximum values of the swallowing (dry and 5 mL of water) pressures at velopharynx, meso-hypopharynx, and at the upper esophageal sphincter (UES) were measured. The resting UES pressure, the length of the part in the cervical esophagus showing the resting UES pressure, and the distances from the nostril to the above-mentioned points of pressure measurement were also measured.

RESULTS

The maximum value of dry and water swallowing pressures at the velopharynx, meso-hypopharynx and UES, and the distances from the nasal vestibulum to each point in men were 141.1 +/- 73.5 (mm Hg, mean +/- standard deviation) and 162.7 +/- 94.9, 175.3 +/- 59.7 and 182.9 +/- 83.6, 172.7 +/- 73.8 and 236.1 +/- 78.9, and 10.0 +/- 1.3 (cm) and 10.1 +/- 1.4, 14.1 +/- 1.5 and 14.4 +/- 1.3, 17.9 +/- 1.7 and 18.0 +/- 1.4, respectively. Those in women were 118.9 +/- 38.0 (mm Hg) and 124.7 +/- 43.4, 165.9 +/- 41.5 and 167.3 +/- 65.0, 149.2 +/- 68.7 and 243.7 +/- 87.4, and 9.5 +/- 1.2 (cm) and 9.4 +/- 1.2, 13.0 +/- 1.5 and 12.8 +/- 1.4, 15.8 +/- 1.5 and 16.0 +/- 1.3, respectively. The maximum value of resting UES pressure, the length of the part in the cervical esophagus showing the resting UES pressure and the distance from the nostril to the mid-point of the width of the resting UES pressure in men and in women were 70.2 +/- 30.0 mm Hg, 4.0 +/- 0.7 cm, 19.1 +/- 1.3 cm, and 61.8 +/- 26.7 mm Hg, 3.6 +/- 0.6 cm, 17.0 +/- 1.2 cm, respectively.

CONCLUSION

The present study provides anatomical and physiological information about normal swallowing along the velopharynx and upper esophagus, which will be an aid to the future clinical and investigative studies.

摘要

目的/假设:本研究旨在证明一种新型高分辨率测压系统的可行性,并确定沿腭咽和食管上段吞咽压力的正常值。

研究设计

前瞻性研究。

方法

对33名无症状的成年日本对照者进行研究。使用一个固态高分辨率测压组件,其有36个周向传感器,间距为1厘米,放置在从腭咽到食管上段的位置,记录吞咽过程中的压力。测量腭咽、中下咽和食管上括约肌(UES)处吞咽(干咽和5毫升水)压力的最大值。还测量了UES静息压力、颈段食管显示UES静息压力部分的长度以及从鼻孔到上述压力测量点的距离。

结果

男性在腭咽、中下咽和UES处干咽和水吞咽压力的最大值,以及从鼻前庭到各点的距离分别为141.1±73.5(毫米汞柱,平均值±标准差)和162.7±94.9、175.3±59.7和182.9±83.6、172.7±73.8和236.1±78.9,以及10.0±1.3(厘米)和10.1±1.4、14.1±1.5和14.4±1.3、17.9±1.7和18.0±1.4。女性的相应值分别为118.9±38.0(毫米汞柱)和124.7±43.4、165.9±41.5和167.3±65.0、149.2±68.7和243.7±87.4,以及9.5±1.2(厘米)和9.4±1.2、13.0±1.5和12.8±1.4、15.8±1.5和16.0±1.3。男性和女性的UES静息压力最大值、颈段食管显示UES静息压力部分的长度以及从鼻孔到UES静息压力宽度中点的距离分别为70.2±30.0毫米汞柱、4.0±0.7厘米、19.1±1.3厘米,以及61.8±26.7毫米汞柱、3.6±0.6厘米、17.0±1.2厘米。

结论

本研究提供了关于腭咽和食管上段正常吞咽的解剖学和生理学信息,这将有助于未来的临床和研究性研究。