Suppr超能文献

窝沟封闭剂对红外荧光测量的影响。

The influence of pit and fissure sealants on infrared fluorescence measurements.

作者信息

Diniz M B, Rodrigues J A, Hug I, Cordeiro R C L, Lussi A

机构信息

Department of Preventive, Restorative and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland.

出版信息

Caries Res. 2008;42(5):328-33. doi: 10.1159/000151327. Epub 2008 Aug 14.

Abstract

The aim of this in vitro study was to evaluate the influence of pit and fissure sealants on fluorescence readings using lasers. We selected 166 permanent molars and randomly divided them into 4 groups which were each treated with a different sealant (a commercially available clear sealant, 2 opaque sealants and an experimental nanofilled clear sealant). The teeth were independently measured twice by 2 experienced dentists using conventional laser fluorescence (LF) and a laser fluorescence pen device (LFpen), before and after sealing, and again after thermocycling to simulate the thermal stressing between the tooth and the dental materials. Friedman test showed no statistically significant changes using LF and LFpen for the commercial clear sealant group, although values tended to increase after sealing. However, the values increased significantly after thermocycling. There was a statistically significant decrease in fluorescence after application of opaque sealants. After application of the experimental nanofilled clear sealant, LF values increased only after thermocycling, whereas the LFpen values increased after sealing and after thermocycling as well. The intraclass correlation coefficient ranged from 0.87 to 0.96 for interexaminer and 0.82 to 0.94 for intraexaminer reproducibility. It was shown that pit and fissure sealants influence LF and LFpen readings, with the values increasing or decreasing according to the material used. In conclusion, both laser fluorescence devices could be useful as an adjunct to detect occlusal caries under unfilled clear sealants. Nevertheless, surfaces sealed with clear nanofilled material could be assessed using only the LF device.

摘要

这项体外研究的目的是评估窝沟封闭剂对激光荧光读数的影响。我们选择了166颗恒牙,随机将它们分为4组,每组用不同的封闭剂进行处理(一种市售的透明封闭剂、两种不透明封闭剂和一种实验性纳米填充透明封闭剂)。在封闭前后以及热循环模拟牙齿与牙科材料之间的热应力后,由2名经验丰富的牙医分别使用传统激光荧光(LF)和激光荧光笔设备(LFpen)对牙齿进行两次独立测量。Friedman检验显示,对于市售透明封闭剂组,使用LF和LFpen测量时,虽封闭后数值有升高趋势,但无统计学显著变化。然而,热循环后数值显著升高。应用不透明封闭剂后荧光有统计学显著下降。应用实验性纳米填充透明封闭剂后,LF值仅在热循环后升高,而LFpen值在封闭后和热循环后均升高。组内相关系数对于检查者间为0.87至0.96,对于检查者内重复性为0.82至0.94。结果表明,窝沟封闭剂会影响LF和LFpen读数,其数值根据所用材料而升高或降低。总之,两种激光荧光设备都可作为检测未填充透明封闭剂下咬合面龋的辅助手段。然而,仅使用LF设备就可以评估用透明纳米填充材料封闭的表面。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验