Suppr超能文献

窝沟封闭剂对荧光摄像系统龋病检测的影响。

Effect of pit and fissure sealants on caries detection by a fluorescent camera system.

机构信息

Department of Oral Biology, New Jersey Dental School, University of Medicine and Dentistry of New Jersey, 185 South Orange Avenue, Newark, NJ 07103, USA.

出版信息

J Dent. 2013 Jul;41(7):590-9. doi: 10.1016/j.jdent.2013.05.005. Epub 2013 May 17.

Abstract

OBJECTIVE

The aim of this study was to evaluate the effect of sealant placement on the detection of caries by a fluorescent camera (FC), the Spectra caries detector.

MATERIALS AND METHODS

In a laboratory study, FC images and readings were obtained from 31 extracted teeth, before and following application of clear sealants (Shofu Clear or Delton unfilled), or opaque sealants (3M Clinpro or Delton FS). Teeth were then sectioned and examined for enamel or dentine caries. Using each tooth's true caries diagnosis, the sensitivity and specificity of the FC measurements in detecting dentine caries was calculated. In the clinical study, FC readings were obtained from 41 molars in children prior to and following application of clear sealants.

RESULTS

Following application of Shofu or Delton unfilled there were reductions in the mean FC readings of 10% (p=0.5) and 8.2% (p=0.009), respectively. Application of two opaque sealants, 3M or Delton FS significantly reduced mean FC readings 16.2% and 20.8% (p<0.5), respectively. Although the carious lesions could still be observed in FC images from teeth with opaque sealants there was a significant loss of sensitivity in detecting dentinal caries. Clear sealant application caused an insignificant loss of detection sensitivity. Following application of clear sealants to children's molars there was a small (4.01%) but significant (p<0.01) reduction in FC readings recorded from these teeth.

CONCLUSIONS

The FC can detect caries under clear sealants with little loss of sensitivity. Although lesions can be seen through opaque sealants, loss of sensitivity precludes accurate lesion assessment.

摘要

目的

本研究旨在评估使用荧光相机(FC)和 Spectra 龋病探测仪检测窝沟封闭剂下龋齿的效果。

材料和方法

在实验室研究中,对 31 颗离体牙进行 FC 成像和读数,在使用透明封闭剂(Shofu Clear 或 Delton 无填料)或不透明封闭剂(3M Clinpro 或 Delton FS)之前和之后。然后将牙齿切片,检查牙釉质或牙本质龋。使用每颗牙齿的真实龋病诊断,计算 FC 测量在检测牙本质龋方面的敏感性和特异性。在临床研究中,在儿童磨牙上应用透明封闭剂前后,用 FC 读取读数。

结果

应用 Shofu 或 Delton 无填料后,FC 读数平均分别降低了 10%(p=0.5)和 8.2%(p=0.009)。应用两种不透明封闭剂,3M 或 Delton FS 后,FC 读数平均分别降低了 16.2%和 20.8%(p<0.5)。尽管在有不透明封闭剂的牙齿的 FC 图像中仍然可以观察到龋损,但检测牙本质龋的敏感性显著降低。透明封闭剂的应用导致检测敏感性的显著丧失。在儿童磨牙上应用透明封闭剂后,从这些牙齿上记录的 FC 读数略有(4.01%)但显著(p<0.01)降低。

结论

FC 可以在透明封闭剂下检测龋齿,而不会降低敏感性。虽然可以通过不透明封闭剂看到病变,但敏感性的丧失排除了对病变的准确评估。

文献AI研究员