Suppr超能文献

血栓弹力图在评估血小板储存期间功能中的应用

[Application of thrombelastography in evaluation of platelet function during storage].

作者信息

Yu Yang, Lin Zi-Lin, Fen Qian, Pan Ji-Chun, Zhang Ting, Sun Gui-Xiang, Zhang Xiao-Juan, Ma Chun-Ya, Ge Guo-Feng, Wang De-Qing, Luo Qun, Tian Ya-Ping

机构信息

Department of Blood Transfusion, Center for Clinical Transfusion Medicine, PLA General Hospital, Beijing 100853, China.

出版信息

Zhongguo Shi Yan Xue Ye Xue Za Zhi. 2008 Aug;16(4):926-9.

Abstract

This study was aimed to explore changes of platelet function in vitro during storage by thrombelastography (TEG). 12 units plateletpheresis were randomly selected and stored at 20 to 24 degrees C with agitation. Thrombelastography variable parameters R, K values and maximal amplitude (MA) were measured on 1, 2, 3, 4, 5 days of platelet storage. Platelet concentration, mean platelet volume (MPV), hypotonic shock response (HSR), CD62p expression and CD62p reexpression on platelet surface were detected at the same time. Changes of platelet function in virto were systematically evaluated by above-mentioned indexes. The results showed that MPV augmented slightly with prolongation of preserved time (p > 0.05), and CD62p expression on platelet surface increased remarkably (p < 0.01), while CD62p reexpression decreased gradually (p < 0.01). There were no significant differences in HSR level of platelets during storage (p > 0.05). R value increased with prolongation of preserved time (p < 0.01). There were no obvious changes on K value and alpha Angle during storage (p > 0.05). There were no obvious changes in MA from 1 to 4 days, and MA decreased slightly on day 5 (p < 0.05). It is concluded that there was no significant change in MA and HSR which reflects comprehensive coagulation of platelets during storage. Platelets on the end of storage have excellent function of hemostasis; Thrombelastography parameter MA value can be used as a valuable indicator for evaluation of platelet function in vitro during storage.

摘要

本研究旨在通过血栓弹力图(TEG)探讨血小板在体外储存期间的功能变化。随机选取12个单位的单采血小板,在20至24摄氏度下振荡保存。在血小板储存的第1、2、3、4、5天测量血栓弹力图可变参数R、K值和最大振幅(MA)。同时检测血小板浓度、平均血小板体积(MPV)、低渗休克反应(HSR)、血小板表面CD62p表达及CD62p再表达。通过上述指标系统评价体外血小板功能变化。结果显示,MPV随保存时间延长略有增加(p>0.05),血小板表面CD62p表达显著增加(p<0.01),而CD62p再表达逐渐降低(p<0.01)。储存期间血小板的HSR水平无显著差异(p>0.05)。R值随保存时间延长而增加(p<0.01)。储存期间K值和α角无明显变化(p>0.05)。1至4天MA无明显变化,第5天MA略有下降(p<0.05)。结论是,反映血小板综合凝血功能的MA和HSR在储存期间无显著变化。储存末期的血小板具有良好的止血功能;血栓弹力图参数MA值可作为评估体外储存血小板功能的有价值指标。

相似文献

3
[Effect of 25 Gy (60)Co Irradiation on the Physico-chemical Property and Functions of the Platelets During Storage].
Zhongguo Shi Yan Xue Ye Xue Za Zhi. 2015 Oct;23(5):1478-82. doi: 10.7534/j.issn.1009-2137.2015.05.049.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验