Suppr超能文献

骨内种植体表面纳米厚度生物陶瓷沉积的组织形态计量学评估:犬的研究。

Histomorphometric evaluation of a nanothickness bioceramic deposition on endosseous implants: a study in dogs.

机构信息

Department of Biomaterials and Biomimetics, New York University, New York, NY, USA.

出版信息

Clin Implant Dent Relat Res. 2009 Dec;11(4):292-302. doi: 10.1111/j.1708-8208.2008.00122.x. Epub 2008 Sep 9.

Abstract

PURPOSE

The objective of this study was to evaluate the bone response to a nanothickness bioceramic ion beam-assisted deposition (IBAD) on endosteal implants in a canine model.

MATERIALS AND METHODS

Alumina-blasted/acid-etched (control) and IBAD-modified (test) implants were characterized by scanning electron microscopy, X-ray photoelectron spectroscopy + ion beam milling, thin-film mode X-ray diffraction, and atomic force microscope. The implants were surgically placed in four dogs' proximal tibiae and remained for 2 and 4 weeks in vivo. Oxytetracycline (10 mg/kg) was administered for bone labeling 48 hours prior to euthanization. Following euthanization, nondecalcified thin sections were prepared for UV and transmitted light microscopy. The amount of bone labeling was evaluated along the length and away from the implant surface by means of a computer software. The % bone-to-implant contact (BIC) was determined for each specimen. One-way analysis of variance at 95% level of significance along with Tukey's post hoc multiple comparisons were utilized for statistical evaluation. The characterization showed Ca- and P-based amorphous coatings with a 20- to 50-nm thickness.

RESULTS

In vivo results showed a significant increase in general and site-specific (to 0.5 mm from the implant surface) bone activity for the 4-week test implants compared with the control implants. Bone activity levels decreased as a function of distance from the implant surface for all groups. No significant differences in BIC were observed between groups.

CONCLUSIONS

This study showed that both surfaces were biocompatible and osteoconductive and that a time-dependent increase in osteoactivity occurred around the test implants.

摘要

目的

本研究旨在评估纳米厚度生物陶瓷离子束辅助沉积(IBAD)对犬模型骨内种植体骨反应的影响。

材料与方法

通过扫描电子显微镜、X 射线光电子能谱+离子束铣削、薄膜模式 X 射线衍射和原子力显微镜对氧化铝喷砂/酸蚀(对照)和 IBAD 改性(试验)种植体进行了表征。将种植体手术植入 4 只犬的胫骨近端,体内植入 2 周和 4 周。在安乐死前 48 小时,给予土霉素(10mg/kg)进行骨标记。安乐死后,制备非脱钙薄切片,进行 UV 和透射光显微镜检查。通过计算机软件沿长度和远离植入物表面评估骨标记的量。确定每个标本的骨-植入物接触百分比(BIC)。利用 95%置信水平的单向方差分析和 Tukey 事后多重比较进行统计评估。表征结果显示具有 20-50nm 厚度的 Ca 和 P 基非晶涂层。

结果

体内结果显示,与对照种植体相比,试验种植体在第 4 周时总体和局部(距种植体表面 0.5mm 处)的骨活性显著增加。所有组的骨活性水平均随距植入物表面距离的增加而降低。各组之间的 BIC 无显著差异。

结论

本研究表明,两种表面均具有生物相容性和骨诱导性,试验种植体周围的成骨活性随时间增加。