Suppr超能文献

石膏模型、数字化模型与重建研究模型准确性的比较。

A comparison of plaster, digital and reconstructed study model accuracy.

作者信息

Keating Andrew P, Knox Jeremy, Bibb Richard, Zhurov Alexei I

机构信息

Regional Orthodontic Unit, Waterford Regional Hospital, Waterford, Ireland.

出版信息

J Orthod. 2008 Sep;35(3):191-201; discussion 175. doi: 10.1179/146531207225022626.

Abstract

OBJECTIVES

To evaluate the accuracy and reproducibility of a three-dimensional (3D) optical laser-scanning device to record the surface detail of plaster study models. To determine the accuracy of physical model replicas constructed from the 3D digital files.

DESIGN AND SETTING

A method comparison study using 30 dental study models held in the Orthodontic Department, School of Dentistry, Cardiff University.

MATERIALS AND METHODS

Each model was captured three-dimensionally, using a commercially available Minolta VIVID 900 non-contact 3D surface laser scanner (Konica Minolta Inc., Tokyo, Japan), a rotary stage and Easy3DScan integrating software (TowerGraphics, Lucca, Italy). Linear measurements were recorded between landmarks, directly on each of the plaster models and indirectly on the 3D digital surface models, on two separate occasions by a single examiner. Physical replicas of two digital models were also reconstructed from their scanned data files, using a rapid prototyping (RP) manufacturing process, and directly evaluated for dimensional accuracy.

RESULTS

The mean difference between measurements made directly on the plaster models and those made on the 3D digital surface models was 0.14 mm, and was not statistically significant (P = 0.237). The mean difference between measurements made on both the plaster and virtual models and those on the RP models, in the z plane was highly statistically significant (P <0.001).

CONCLUSIONS

The Minolta VIVID 900 digitizer is a reliable device for capturing the surface detail of plaster study models three-dimensionally in a digital format but physical models of appropriate detail and accuracy cannot be reproduced from scanned data using the RP technique described.

摘要

目的

评估三维(3D)光学激光扫描设备记录石膏研究模型表面细节的准确性和可重复性。确定从3D数字文件构建的物理模型复制品的准确性。

设计与设置

使用卡迪夫大学牙科学院正畸科保存的30个牙科研究模型进行方法比较研究。

材料与方法

使用市售的柯尼卡美能达VIVID 900非接触式3D表面激光扫描仪(日本东京柯尼卡美能达公司)、旋转台和Easy3DScan集成软件(意大利卢卡TowerGraphics公司)对每个模型进行三维捕捉。由一名检查者在两个不同时间,直接在每个石膏模型上以及间接在3D数字表面模型上记录地标之间的线性测量值。还使用快速成型(RP)制造工艺从其扫描数据文件重建了两个数字模型的物理复制品,并直接评估其尺寸精度。

结果

直接在石膏模型上进行的测量与在3D数字表面模型上进行的测量之间的平均差异为0.14毫米,无统计学意义(P = 0.237)。在z平面上,石膏模型和虚拟模型上的测量值与RP模型上的测量值之间的平均差异具有高度统计学意义(P <0.001)。

结论

柯尼卡美能达VIVID 900数字化仪是一种可靠的设备,可将石膏研究模型的表面细节以数字格式进行三维捕捉,但使用所述的RP技术无法从扫描数据中复制出具有适当细节和精度的物理模型。