Abstract

PURPOSE

To better understand the reference values and adequate discrimination values of colour vision function with described quantitative systems for the Lanthony desaturated D-15 panel (D-15DS).

METHODS

A total of 1042 Japanese male officials were interviewed and underwent testing using Ishihara pseudoisochromatic plates, standard pseudoisochromatic plates part 2, and the D-15DS. The Farnsworth-Munsell (F-M) 100-hue test and the criteria of Verriest et al were used as definitive tests. Outcomes of the D-15DS were calculated using Bowman's Colour Confusion Index (CCI). The study design included two criteria. In criterion A, subjects with current or past ocular disease and a best-corrected visual acuity less than 0.7 on a decimal visual acuity chart were excluded. In criterion B, among subjects who satisfied criterion A, those who had a congenital colour sense anomaly were excluded.

RESULTS

Overall, the 90th percentile (95th percentile) CCI values for criteria A and B in the worse eye were 1.70 (1.95) and 1.59 (1.73), respectively. In subjects satisfying criterion B, the area under the receiver operating characteristic curve was 0.951 (95% confidence interval, 0.931-0.971). The CCI discrimination values of 1.52 or 1.63 showed 90.3% sensitivity and 90% specificity, or 71.5% sensitivity and 95% specificity, respectively, for discriminating acquired colour vision impairment (ACVI).

CONCLUSION

We provided the 90th and 95th percentiles in a young to middle-aged healthy population. The CCI is in good agreement with the diagnosis of ACVI. Our results could be helpful for using D-15DS for screening purposes.

摘要

目的

通过描述用于 Lanthony 去饱和 D-15 面板(D-15DS)的定量系统,更好地了解色觉功能的参考值和充分的判别值。

方法

对 1042 名日本男性公务员进行了访谈,并使用石原色盲测试板、标准假同色板第 2 部分和 D-15DS 进行了测试。Farnsworth-Munsell(F-M)100 色调测试和 Verriest 等人的标准被用作确定测试。D-15DS 的结果使用 Bowman 颜色混淆指数(CCI)进行计算。研究设计包括两个标准。在标准 A 中,排除当前或过去有眼部疾病且在十进制视力表上最佳矫正视力小于 0.7 的受试者。在标准 B 中,在满足标准 A 的受试者中,排除先天性色觉异常的受试者。

结果

总体而言,在较差眼的标准 A 和标准 B 中,90 百分位(95 百分位)CCI 值分别为 1.70(1.95)和 1.59(1.73)。在满足标准 B 的受试者中,受试者工作特征曲线下的面积为 0.951(95%置信区间,0.931-0.971)。CCI 判别值为 1.52 或 1.63 时,分别对获得性色觉障碍(ACVI)的敏感性为 90.3%,特异性为 90%,或敏感性为 71.5%,特异性为 95%。

结论

我们提供了年轻到中年健康人群的 90 百分位和 95 百分位。CCI 与 ACVI 的诊断结果一致。我们的结果可能有助于使用 D-15DS 进行筛查。