Ottaway J M, Whymark D W, Metters B, Cooksey B G
Department of Pure and Applied Chemistry, University of Strathclyde Cathedral Street, Glasgow, C.1 U.K.
Talanta. 1971 Aug;18(8):773-8. doi: 10.1016/0039-9140(71)80127-3.
It is demonstrated that the addition of 5% of water to the non-aqueous solvent for the titrimetric determination of carbon in steel improves the performance of the titration. Modifications to the procedure are proposed which allow the normal titrant, tetra-n-butylammonium hydroxide dissolved in benzene-methanol, to be replaced by an aqueous solution of potassium hydroxide. The proposed procedure has been applied to the analysis of a wide range of standard steel samples.